HP ProLiant Smart Array E200 Uživatelská příručka Strana 60: Using a PCI SAS or SATA array controller to support six hard drives

/ 118
Obsah
Řešení problémů
Hardware options installation
60
CAUTION:
When routing cables, always be sure that the cables are not in a position where they can be
pinched or crimped.
7.
Install fan modules 1 and 2 ("
Remove and install a fan module
" on page
22
).
8.
Install the air baffle.
9.
Install the access panel (on page
20
).
10.
Slide the server into the rack.
11.
Power up the server (on page
18
).

Using a PCI SAS or SATA array controller to support six hard drives

1.
Power down the server (on page
18
).
2.
Extend the server from the rack (on page
19
).
3.
Remove the access panel (on page
20
).
4.
Remove the air baffle. ("
Remove the power supply air baffle
" on page
21
, "
Remove the processor
air baffle
" on page
22
)
5.
Remove fan modules 1 and 2 ("
Remove and install a fan module
" on page
22
).
6.
Disconnect all cables from the currently-installed HP Smart Array E200i Controller or HP Smart Array
P400i Controller.