HP SG3-200 - Desktop PC Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebones pro PC / pracovní stanice HP SG3-200 - Desktop PC. HP SG3-200 - Desktop PC User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 84
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
CANDU-9 COMPACT SIMULATOR
USER MANUAL
Lecture Notes
prepared by:
Dr. George Bereznai
Dean, Energy Management and
Nuclear Science, at the University of
Ontario Institute of Technology,
Canada
Zobrazit stránku 0
1 2 3 4 5 6 ... 83 84

Shrnutí obsahu

Strany 1 - USER MANUAL

CANDU-9 COMPACT SIMULATOR USER MANUAL Lecture Notes prepared by: Dr. George Bereznai Dean, Energy Management and Nuclear Science, at the University of

Strany 2

Simulator User Manual 1.4 COMPACT SIMULATOR DISPLAY COMMON FEATURES The CANDU 9 Compact Simulator is made up of 16 interactive display screens or pag

Strany 3

Simulator User Manual page 7

Strany 4

Simulator User Manual 2. SIMULATOR DISPLAY PAGES 2.1 PLANT OVERVIEW PAGE Shows a ‘line diagram’ of the main plant systems and parameters. No inputs

Strany 5

Simulator User Manual Six trend displays show the following parameters: • Reactor Neutron Power and Reactor Thermal Power (0-100%) • Turbine Power (

Strany 6

Simulator User Manual 2.2 SHUTDOWN RODS PAGE The screen shows the status of SDS#1, as well as the reactivity contributions of each device and physica

Strany 7

Simulator User Manual page 11

Strany 8 - 16. UPR

Simulator User Manual 2.3 REACTIVITY CONTROL PAGE This screen shows the Limit Control Diagram, and the status of the three reactivity control devices

Strany 9

Simulator User Manual page 13

Strany 10 - Simulator User Manual

Simulator User Manual 2.4 PHT MAIN CIRCUIT This screen shows a simplified layout of the main heat transport system: the 480 coolant channels are repr

Strany 11

Simulator User Manual page 15

Strany 13

Simulator User Manual 2.5 PHT FEED AND BLEED This screen shows the Heat Transport pressure control system, including the pressurizer, bleed (or de-ga

Strany 14

Simulator User Manual page 17

Strany 15

Simulator User Manual 2.6 PHT INVENTORY CONTROL The screen shows the parameters relevant to controlling the inventory in the main heat transport loop

Strany 16

Simulator User Manual page 19

Strany 17

Simulator User Manual 2.7 PHT PRESSURE CONTROL This screen is similar to the previous one in terms of the ability to select PHT Pressure Control MODE

Strany 18

Simulator User Manual page 21

Strany 19

Simulator User Manual 2.8 BLEED CONDENSER CONTROL The parameters required to control Bleed Condenser Pressure and Level are shown on this screen. •

Strany 20

Simulator User Manual page 23

Strany 21

Simulator User Manual 2.9 STEAM GENERATOR FEED PUMPS PAGE Screen shows the portion of the feedwater system that includes the Deaerator, the boiler fe

Strany 22

Simulator User Manual page 25

Strany 23

CONTENTS 1. INTRODUCTION 1.1 SIMULATOR STARTUP 1.2 SIMULATOR INITIALIZATION 1.3 LIST OF CANDU 9 COMPACT SIMULATOR DISPLAY SCREENS 1.4 COMPACT SIMULAT

Strany 24

Simulator User Manual 2.10 STEAM GENERATOR LEVEL CONTROL PAGE Screen shows each of the four boilers and associated level control valves. The followi

Strany 25

Simulator User Manual page 27

Strany 26

Simulator User Manual 2.11 STEAM GENERATOR LEVEL TRENDS PAGE Screen shows the steam generator level displays, including the actual level, the alarm,

Strany 27

Simulator User Manual page 29

Strany 28

Simulator User Manual 2.12 STEAM GENERATOR LEVEL MANUAL CONTROL • This screen allows the manual control of the level in each of the four steam gener

Strany 29

Simulator User Manual page 31

Strany 30

Simulator User Manual 2.13 EXTRACTION STEAM PAGE Screen shows the extraction steam flows from the Main Steam system to the Deaerator and the High Pres

Strany 31

Simulator User Manual page 33

Strany 32

Simulator User Manual 2.14 TURBINE GENERATOR PAGE Shows the main parameters and controls associated with the Turbine and the generator. The paramete

Strany 33

Simulator User Manual page 35

Strany 35

Simulator User Manual 2.15 RRS / DPR PAGE This screen permits control of reactor power setpoint and its rate of change while under Reactor Regulating

Strany 36

Simulator User Manual page 37

Strany 37

Simulator User Manual 2.16 UPR PAGE This screen permits control of station load setpoint and its rate of change while under Unit Power Regulator (UPR)

Strany 38

Simulator User Manual page 39

Strany 39

Simulator User Manual 2.17 TREND This screen shows the trend plots for eight simulated plant parameters. The list below gives the parameter names that

Strany 40

Simulator User Manual page 41

Strany 42

CANDU-9 COMPACT SIMULATOR EXERCISES Lecture Notes prepared by: Dr. George Bereznai Dean, Energy Management and Nuclear Science, at the University of O

Strany 44

CONTENTS1. OVERALL UNIT CONTROL 1.1 POWER MANEUVER 1.2 RESPONSE TO POWER MANEUVER (NORMAL MODE) 1.3 TEMPERATURE PROFILE ACROSS A CANDU 9 UNIT 2.

Strany 45

Simulator User Manual 1. INTRODUCTION The CANDU-9 Compact Simulator was originally developed to assist Atomic Energy of Canada Limited (AECL) in the d

Strany 47 - EXERCISES

1. OVERALL UNIT CONTROL 1.1 POWER MANEUVER: 10% Power Reduction and Return to Full Power (1) Initialize Simulator to 100% full power; (2) verify t

Strany 49

1.2 RESPONSE TO POWER MANEUVER (NORMAL MODE) • Initialize the Simulator to 100%FP, reduce power using UPR in 25% steps at 0.5%/sec (trip the reacto

Strany 50

1.3 TEMPERATURE PROFILE ACROSS A CANDU 9 UNIT AT FULL POWER (1) Initialize the Simulator to 100% Full Power; (2) record the missing values of the p

Strany 51

350 300 250 200 Temp °C 150 100 50 0 PRIMARY SIDE SECONDARY SIDE Pump Reactor Reactor Pump Steam HP LP Con- LP De- Boiler HP Preheat Suction Inl

Strany 52

2. REACTOR REGULATING SYSTEM OPERATION 2.1 POWER MANEUVER IN ‘ALTERNATE’ MODE (1) Initialize the Simulator to 100%FP, select ‘ALTERNATE MODE”, and

Strany 53

ASSIGNMENT: (a) Explain the changes in Average Zone Level between each operating state (column): • (1) → (2) • (2) → (3) • (3) → (4) • (4) → (5)

Strany 54

2.2 RESPONSE OF RRS CONTROL ALGORITHM TO POWER MANEUVER (1) Initialize the Simulator to 100%FP and from the Reactivity Control page note the positio

Strany 55

2.3 REACTOR AND RRS RESPONSE TO POWER MANEUVER (1) Initialize the Simulator to 100%FP and from the Reactivity Control page note the position of the

Strany 56

Simulator User Manual page 2

Strany 57

2.4 POWER MANEUVER UNDER MANUAL CONTROL (1) Initialize the Simulator to 100%FP and select ALTERNATE MODE. On the Reactivity Control page place the c

Strany 58

2.5 MANUAL WITHDRAWAL OF ADJUSTER RODS (1) Initialize the Simulator to 100%FP and select ALTERNATE MODE. On the Reactivity Control page place the co

Strany 59

3. REACTOR REGULATING SYSTEM MALFUNCTIONS AND TRIPS 3.1 FAIL OPEN LIQUID ZONE INLET VALVES (1) Initialize the Simulator to 100%FP, select ALTERNATE

Strany 60

3.2 FAIL CLOSED LIQUID ZONE INLET VALVES (1) Initialize the Simulator to 100%FP, select ALTERNATE MODE, and go to the Reactivity Control page; (2)

Strany 61

3.3 ONE BANK OF ABSORBER RODS DROP (1) Initialize the Simulator to 100%FP and from the Reactivity Control page note the position of the operating po

Strany 62

3.4 SDS#1 REACTOR TRIP AND RECOVERY Check the time calibration factor of the Simulator on your computer, and compute the real time response by multip

Strany 63

3.5 SDS#1 REACTOR TRIP AND POISON-OUT (1) Initialize the Simulator to 100%FP; (2) manually trip the reactor; (3) observe the response of the overa

Strany 64

3.6 SDS#1 REACTOR TRIP AND POISON OVERRIDE Before starting this exercise make sure that you do a time calibration of your simulator and that all time

Strany 65

4. HEAT TRANSPORT SYSTEM EXERCISES 4.1 PHT LRV (CV20) FAILS OPEN (1) Initialize the Simulator to the 100% full power state; (2) record the initial

Strany 66

4.2 PHT STEAM BLEED VALVE (CV22) FAILS OPEN (1) Initialize the Simulator to the 100% full power state; (2) record the initial parameter values; (3)

Strany 67

Simulator User Manual Table 1: Summary of Simulator Features. SYSTEM SIMULATION SCOPE DISPLAY PAGES OPERATOR CONTROLS MALFUNCTIONS REACTOR • neutron

Strany 68

4.3 PHT FEED VALVE (CV12) FAILS OPEN (1) Initialize the Simulator to the 100% full power state; (2) record the initial parameter values; (3) inser

Strany 69

4.4 PRZR SURGE VALVE (MV1) FAILS CLOSED (1) Initialize the Simulator to the 100% full power state; (2) record the initial parameter values; (3) in

Strany 70

4.5 PHT BLEED VALVE (CV5) FAILS OPEN (1) Initialize the Simulator to the 100% full power state; (2) record the initial parameter values; (3) inser

Strany 71

5. STEAM AND FEEDWATER SYSTEM EXERCISES 5.1 FW LCV101 FAILS OPEN (1) From a Simulator Initial state of 100% full power, insert the malfunction

Strany 72

5.2 FW LCV101 FAILS CLOSED (1) Initialize the Simulator to 100 %FP; (2) change ‘Control Mode Select’ to OPERa

Strany 73

5.3 STEAM GENERATOR #1 FW FT IRRATIONAL (1) Initialize the Simulator to 100 %FP; (2) insert malfunction “STEAM GENERATOR #1 FW FT IRRATIONAL”. ASSI

Strany 74

5.4 STEAM GENERATOR PRESSURE CONTROL EXERCISE Using Simulator pages ‘Plant Overview’, ‘Turbine-Generator’ and ‘UPR’, design a procedure to verify the

Strany 75

5.5 REACTOR TRIP AND UNIT RECOVERY (1) Initialize the Simulator to 100 %FP; (2) manually Trip the Reactor; (3) confirm Reactor Trip (neutron power

Strany 76

6. OVERALL UNIT EXERCISES Begin each of the following exercises from the Plant Overview page. Initialize the Simulator to 100% FP. Before inserting t

Strany 77

6.1 FAIL CLOSED ALL FEEDWATER LEVEL CONTROL VALVE MOTORIZED VALVES (1) Observe the main parameter changes that take place in the first minute, in pa

Strany 78

Simulator User Manual 1.1 SIMULATOR STARTUP • select program ‘CANDU-9’ for execution • click anywhere on ‘CANDU-9 Compact Simulator” screen • clic

Strany 79

6.2 ALL MAIN BFPs TRIP ASSIGNMENT: Describe the unit’s response and explain the main differences between the responses to this malfunction and the o

Strany 80 - ASSIGNMENT:

6.3 TURBINE SPURIOUS TRIP ASSIGNMENT: (a) List the initial alarms after the malfunction had been inserted. (b) Describe the “state” (main energy ba

Strany 81

6.4 THROTTLE PT (PRESSURE TRANSMITTER) FAILS LOW ASSIGNMENT: (a) List the initial alarms after the malfunction had been inserted. (b) Describe the

Strany 82

6.5 RIH#1 SMALL BREAK (a) List the initial alarms after the malfunction had been inserted. (b) Describe the “state” (main energy balance) of the un

Strany 83

6.6 MAIN STEAM HEADER BREAK (a) List the initial alarms after the malfunction had been inserted. (b) Describes the “state” (main energy balance) of

Strany 84

Simulator User Manual page 5

Komentáře k této Příručce

Žádné komentáře