HP SL6000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery HP SL6000. HP SL6000 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 25
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP ProLiant SL6000 Scalable System technology
technology brief
Abstract.............................................................................................................................................. 3
Mechanical design for extreme scale-out computing................................................................................. 3
HP ProLiant z6000 G6 chassis .......................................................................................................... 4
Rack and cabling options.................................................................................................................. 4
SL6000 server trays ......................................................................................................................... 5
HP ProLiant SL160z G6 server ....................................................................................................... 7
HP ProLiant SL170z G6 server ....................................................................................................... 8
HP ProLiant SL2x170z G6 server ................................................................................................... 9
Intel Xeon 5500 Series processor technology ........................................................................................ 10
Multi-level caches........................................................................................................................... 11
QuickPath Interconnect controller ..................................................................................................... 12
Hyper-Threading ............................................................................................................................ 12
Turbo Boost technology................................................................................................................... 13
Processor socket technology................................................................................................................ 13
Memory technologies ......................................................................................................................... 14
DDR3 memory enhancements .......................................................................................................... 14
Controlled fan speed .................................................................................................................. 14
Reduced operating voltage.......................................................................................................... 14
Unbuffered and registered DIMMs ................................................................................................... 15
I/O technologies ............................................................................................................................... 16
PCI Express technology................................................................................................................... 16
Serial ATA technology .................................................................................................................... 16
Networking technologies ................................................................................................................ 17
High Performance Computing technologies ....................................................................................... 17
Power and thermal technologies.......................................................................................................... 17
Power supply options...................................................................................................................... 18
Redundant power operation ............................................................................................................ 18
Management and deployment............................................................................................................. 20
Systems management and monitoring............................................................................................... 20
Power and thermal management with the Power Management Controller ............................................. 20
Remote management and control with ProLiant Onboard Administrator ................................................ 22
IPMI 2.0 and DCMI 1.0.................................................................................................................. 22
Server deployment ......................................................................................................................... 23
Data security technology with the Trusted Platform Module ..................................................................... 23
Summary .......................................................................................................................................... 23
Zobrazit stránku 0
1 2 3 4 5 6 ... 24 25

Shrnutí obsahu

Strany 1

HP ProLiant SL6000 Scalable System technology technology brief Abstract...

Strany 2

Because two server nodes are installed side-by-side, the front of the unit has twice as many ports and LEDs as the SL170z G6 server. Each server node

Strany 3 - Abstract

Multi-level caches Intel Xeon 5500 Series processors have a three-level cache hierarchy (Figure 9): • An on-core 64-kilobyte Level 1 cache, split in

Strany 4 - Rack and cabling options

QuickPath Interconnect controller Intel Xeon 5500 Series processors attain their performance potential through Intel QuickPath architecture (Figure 1

Strany 5 - SL6000 server trays

Turbo Boost technology Intel Turbo Boost Technology complements Hyper-Threading by increasing the performance of both multi-threaded and single-threa

Strany 6

Figure 12. Diagram showing how the processor installation tool simplifies installation Memory technologies Xeon 5500 Series processors connect dir

Strany 7

Unbuffered and registered DIMMs DDR3 DIMMs are available as both Unbuffered (UDIMMs) and Registered (RDIMMs). Both UDIMMs and RDIMMs support error co

Strany 8

For detailed memory configuration guidelines, use the Online DDR3 Memory Configuration Tool available on the HP website: www.hp.com/go/ddr3memory-con

Strany 9

throughput and improve the ability to locate and fix disk failures. More importantly, serial architecture solves the problems of clock skew and signa

Strany 10

Power supply options Common slot power supplies come in multiple power ratings and have achieved efficiency ratings of up to 92 percent. Three power

Strany 11 - Multi-level caches

Full AC or DC redundancy requires two power supplies to run the z6000 chassis. If one power supply fails and the remaining power supply can meet pow

Strany 12 - Hyper-Threading

Appendix: PPIC command line utility... 24 For more i

Strany 13 - Processor socket technology

In a multimode environment, it is important to ensure that planning is completed prior to selecting the right power supply for the desired redundancy

Strany 14 - Memory technologies

Figure 16. HP ProLiant z6000 G6 chassis node, fan, and power control block diagram Power control logic in the z6000 G6 chassis operates in one of

Strany 15

Remote management and control with ProLiant Onboard Administrator All ProLiant SL servers include ProLiant Onboard Administrator powered by LO100i.

Strany 16 - I/O technologies

Server deployment The HP ProLiant Easy Set-up CD provides easy, step-by-step, single- and multi-server server utilities to streamline server setup. I

Strany 17 - Networking technologies

24 Appendix: PPIC command line utility HP provides a simple command line utility, called PPIC, for reading and configuring the power control logic of

Strany 18 - Redundant power operation

For more information For additional information, refer to the resources listed below. Resource description Web address HP ProLiant SL160z G6 Server

Strany 19

Abstract The HP ProLiant SL6000 Scalable System implements an entirely new mechanical design and architecture in the industry-standard server market.

Strany 20 - Management and deployment

Figure 1. HP ProLiant SL6000 Scalable System HP ProLiant z6000 G6 chassis The HP ProLiant Scalable System implements a new chassis/rack architect

Strany 21

Figure 2. Front and rear views of HP 42U rack fully populated with SL6000 systems SL6000 server trays HP developed multiple SL6000 server trays to

Strany 22 - IPMI 2.0 and DCMI 1.0

For easy servicing, video and serial ports, USB ports, NIC ports, and optional out-of-band management LAN ports are located on the front panel of eac

Strany 23 - Summary

HP ProLiant SL160z G6 server The SL160z G6 server tray is optimized for maximum expansion (Figure 5). The system board accommodates up to two Intel X

Strany 24

HP ProLiant SL170z G6 server The HP ProLiant SL170z G6 server tray is optimized for maximum storage capability (Figure 6). It supports LFF, SFF, or S

Strany 25 - Call to action

HP ProLiant SL2x170z G6 server The HP ProLiant SL2x170z G6 server tray is optimized for compute power and density (Figure 7). It contains two SL170z

Komentáře k této Příručce

Žádné komentáře