HP 3PAR Uživatelská příručka
Procházejte online nebo si stáhněte Uživatelská příručka pro Software HP 3PAR. HP 3PAR Reference Guide [en] [es] [fr] Uživatelská příručka
HP 3PAR S-Class/T-Class Storage System
Physical Planning Manual
Soubor PDF · ·
Shrnutí obsahu
HP 3PAR S-Class/T-Class Storage System Physical Planning Manual Abstract This manual provides information that is useful for planning and preparing…
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties…
Contents 1 System Components and Specifications 5 HP 3PAR Storage System Components 5 S400/S800 HP 3PAR Storage System Specifications 7 Physical…
Supported Network Topologies 37 Shared Network 37 Private Network 38 TCP/IP Port Assignments 39 Fibre Channel Connections 41 Required Cables 43…
This chapter provides detailed system specifications for the HP 3PAR S-Class and T-Class Storage systems and serves as a quick reference for other…
Figure 1 The Front of an S-Class or T-Class HP 3PAR Storage System
Figure 2 The Rear View of an S-Class or T-Class HP 3PAR Storage System S400/S800 HP 3PAR Storage System Specifications HP 3PAR S400 and S800 Storage…
Table 1 S400/S800 Storage System Physical Specifications (continued) S400/S800 Storage System Physical Specifications 223.4 kg492.5 lbs.Maximum Weight…
T400/T800 HP 3PAR Storage System Specifications HP 3PAR T400 and T800 Storage systems accommodate up to four or eight controller nodes, respectively.…
Table 4 T400/T800 Storage System Capacity Specifications (continued) T800T400Feature 6:2, 14:26:2, 14:2RAID 6 data to parity ratios 50 GB SSD, 146 GB…
Table 5 T-Class Storage System Power Requirements (continued) 160208BTUs/hour 4 x 450 GB FC Drive Magazines 5788Watts 194300BTUs/hour 4 x 600 GB FC…
Table 6 Environmental Specifications for HP 3PAR Storage systems (continued) ValueSpecification 0–3,000 ft (914.4 m) 50 –95° F (10 –35° C)…
This chapter provides general recommendations for physical planning and site preparation for installation and operation of the HP 3PAR S-Class and…
Verify that electrical service wiring has been installed at the server’s predetermined location. Refer to the respective product specifications for…
package for obvious damage or signs of tampering and notify both HP and the carrier of any issues. Shipping container measurements are as follows…
Figure 4 Front View of the Cabinet Shipping Container The equipment is removed from the front of the container by pulling on two straps that wrap…
Figure 5 Front View of the Container with Ramp Down Acclimatization HP 3PAR Storage systems shipped or stored at extreme temperatures may require time…
You should consider the following when choosing or designing your facilities for HP 3PAR Storage systems: Equipment location and layout that allows…
Table 10 Raised Floor Specifications ValueSpecification Less than 0.06 in. (1.5 mm) Less than 0 .10 in. (2.5 mm) Flatness tolerance Per 10 ft (3 m)…
However, before placing a cabinet on floor tiles shared with other cabinets or equipment, first verify that the floor panels can tolerate the weight…
Figure 8 Tile Cutout Specifications WARNING! To prevent potential collapse, loaded floor panels that have cutouts to facilitate cable routing may…
Figure 9 Front View Dimensions for the HP 3PAR Storage System Figure 10 Side View Dimensions for the HP 3PAR Storage System Figure 11 Bottom View…
Additional Flooring Recommendations Consider the following recommendations for raised floor installations: The flooring should be high enough to allow…
Figure 12 Hot-Aisle/Cold-Aisle Layout Form rows of racks or cabinets perpendicular to air conditioners. This formation facilitates an unobstructed…
NOTE: The S800 and T800 Storage systems have circuit breakers located at both the front and rear of the system. It is necessary to maintain access to…
percent of the load, whereas the dry heat of electronic equipment produces a sensible heat ratio of over 95 percent. Prior to installation, verify…
recommendations for outside air in comfort air-conditioning are 10 to 15 percent of the airflow, the computer room environment is cleaner and operates…
This chapter describes the general power requirements for the HP 3PAR Storage systems. Powering HP 3PAR Storage Systems The cabinets used to house the…
NOTE: If a storage system cabinet does not have components installed in the top four bays (bays 0–3, or the highest 16U of the cabinet), the two upper…
Figure 15 Power Banks in the PDU WARNING! To avoid possible injury, damage to storage system equipment, and potential loss of data, do not use the…
Zobrazit všech 53 stran
NOTE: When routing the power cords through the bottom of the 2 meter cabinet, the usable cord length extends 9.5 to 10 feet away from the cabinet. If…
Installing a lightning protection device on the server room power source is recommended when the following conditions exist: The primary power is…
Figure 17 Front View of the Power Domains Within the Controller Nodes and Drive Chassis Redundant Power 33
Figure 18 Rear View of the Power Domains Within the Controller Nodes and Drive Chassis WARNING! To avoid possible injury, damage to storage system…
Figure 19 Redundant Power Configuration Diagram (S800 and T800) Table 15 Redundant Power Configuration (S800 and T800) AC CordPower BankPDU Number…
Table 15 Redundant Power Configuration (S800 and T800) (continued) AC CordPower BankPDU Number 7-R,8-R13 5-L,6-L23
This chapter provides information about determining the best network configuration for the HP 3PAR Storage systems being installed at your site…
Figure 20 Storage System and SP on the Customer Network (Shared Topology) A shared topology requires: A static IP address and system name for the…
NOTE: It is strongly recommended that the private network segment also have a management station to communicate with the SP. NOTE: This configuration…
Table 16 TCP/IP Port Usage Table (continued) Flow of TrafficUsagePort Passes unsolicited events from the storage system and is used by the following…
Table 16 TCP/IP Port Usage Table (continued) Flow of TrafficUsagePort HP 3PAR CIM Server 3rd Party CIM Client <--> HP 3PAR CIM Server Not part of an…
Figure 22 S-Class Controller Node Fibre Channel Ports (Dual-Port Adapters) Figure 23 T-Class Controller Node Fibre Channel Ports (Dual-Port Adapters)
Fibre Channel adapters can have either two ports (dual-port adapters ) or four ports (quad-port adapters). Required Cables The quantities and lengths…
To provide redundancy and to permit online software upgrades, both controller nodes in a single horizontal node pair (for example, nodes 0 and 1…
Cable Routing Options Storage system cabinets have both upper and lower access openings available for Fibre Channel cable routing (Figure 24 (page…
Table 21 SP Connections ConfigurationConnection type For SP: connection from the RJ-45 connector in the ETH 0 port at the rear of the SP to an…
Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the…
See:For information about: HP 3PAR-to-3PAR Storage Peer Motion GuideMigrating data from one HP 3PAR storage system to another HP 3PAR Secure Service…
See:For information about: Planning for HP 3PAR storage system setup Hardware specifications, installation considerations, power requirements…
HP 3PAR Service Processor Software User Guide: Service Edition Initializing and using the Service Processor HP 3PAR Service Processor Software Upgrade…
Typographic conventions Table 22 Document conventions ElementConvention Bold text Keys that you press Text you typed into a GUI element, such as a…
7 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors…
A Regulatory information For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage…
Další dokumenty pro Software HP 3PAR
HP 3PAR Uživatelská příručka
(676 stránek)
HP 3PAR Uživatelský manuál
(51 stránek)
HP 3PAR Uživatelský manuál
(89 stránek)
HP 3PAR Uživatelský manuál
(53 stránek)
HP 3PAR Uživatelský manuál
(24 stránek)
HP 3PAR Uživatelský manuál
(475 stránek)
HP 3PAR Uživatelský manuál
(184 stránek)
HP 3PAR Průvodce řešením problémů
(127 stránek)
HP 3PAR Uživatelská příručka
(97 stránek)
HP 3PAR Uživatelská příručka
(144 stránek)
HP 3PAR Uživatelský manuál
(63 stránek)
HP 3PAR Rychlý návod
(2 stránky)
HP 3PAR Instalační manuál
(2 stránky)
Otázky k HP 3PAR
K tomuto návodu zatím nejsou žádné otázky. Položte první.
Související produkty a manuály pro Software HP 3PAR
- Software HP 11i Uživatelský manuál
(557 stránek) - Software HP IA-64 Uživatelský manuál
(110 stránek) - Software HP 3PAR Uživatelský manuál
(475 stránek) - Software HP 4GB Uživatelský manuál
(292 stránek) - Software HP 3PAR Instalační manuál
(2 stránky) - Software HP X9320 Uživatelská příručka
(198 stránek) - Software HP Switch 6208M-SX Uživatelský manuál
(710 stránek) - Software HP XP20000 Uživatelský manuál
(122 stránek) - Software HP PROCURVE 2300 Uživatelský manuál
(270 stránek) - Software HP B6191-90028 Uživatelský manuál
(115 stránek) - Software HP 11i Instalační manuál
(20 stránek) - Software HP Integrity NonStop Release and Migration Rychlý návod
(1 stránka) - Software HP Netsight Uživatelský manuál
(238 stránek) - Software HP CloudSystem Enterprise Uživatelská příručka
(150 stránek) - Software HP Insight Control Data Center Edition 12.211 Uživatelský manuál
(4 stránky) - Software HP P9500 Uživatelský manuál
(494 stránek) - Software HP X9320 Uživatelský manuál
(125 stránek) - Software HP 8/20q Uživatelská příručka
(5 stránek) - Software HP Data Explorer 4 Series Uživatelský manuál
(447 stránek) - Software HP 3PAR Uživatelská příručka
(144 stránek)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53