Updating SWAN Concentrator CLIP Firmware
G06.24 Software Installation and Upgrade Guide—528593-005
C-10
Check Location and Version of New SWAN CLIP
Firmware
Check Location and Version of New SWAN CLIP Firmware
The SWAN firmware object code file is a 510 disk file that resides on a NonStop
S-series server and is downloaded to the SWAN concentrator CLIP.
Check the location and version of the SWAN firmware object code file for the G06.24
RVU. At a TACL prompt, enter the VPROC command:
VPROC $SYSTEM.CSSnn.C7953P00
where nn is the number specified during the Build/Apply phase of installing the
G06.24 RVU. For example:
9> vproc $system.css04.c7953p00
VPROC - T9617G03 - (30 MAR 1999) SYSTEM \ELI Date 22 SEP 2000, 22:47:24
COPYRIGHT TANDEM COMPUTERS INCORPORATED 1986 - 1995
$SYSTEM.CSS04.C7953P00
Binder timestamp: 23JUL2000 17:04:56
Version procedure: T7954G01^28JUN2000^AAI^R004
Version procedure: T7953G01^28JUN2000^AAI^R004
Version procedure: T5814G01^28JUN2000^AAI^R004
Version procedure: T7955F40^28JUN2000^AAI^R004
Version procedure: T7848F40^28JUN2000^AAI^R004
Check Firmware Version Currently Running in SWAN CLIPs
Determine the firmware version currently running in each SWAN CLIP in one of these
ways:
•
Use the TSM Service Application to show the attributes of each CLIP. For example:
VST400.vsd