Release Notes: Version M.10.72 Software
for the HP ProCurve Series 3400cl Switches
"M” software versions are supported on these switches:
Release M.10.41 supports the ProCurve Switch 3400cl-24G (J4905A), and 3400cl-48G (J4906A).
These release notes include information on the following:
Downloading switch software and documentation from the Web (page 1)
Clarification of operating details for certain software features (page 20)
A listing of software enhancements in recent releases (page 25)
A listing of software fixes included in releases M.08.51 through M.10.72 (page 145)
IMPORTANT:
3400cl switches MUST be running ROM version I.08.12 prior to loading M.10.20 or newer software. If your
switch is using a software version earlier than M.10.10, you need to install and boot the M.10.10 software
(included in the M.10.41 software package) to load the I.08.12 ROM version, before installing M.10.20 or
newer.
Security Note:
Downloading and booting software release M.08.89 or greater for the first time automatically enables
SNMP access to the hpSwitchAuth MIB objects. If this is not desirable for your network, ProCurve
recommends that you disable it after downloading and rebooting with the latest switch software. For more
information, refer to “Enforcing Switch Security” on page 10 and “Using SNMP To View and Configure
Switch Authentication Features” on page 35.
Configuration Compatibility Caution:
Configuration files created or saved using version M.10.65 or higher are NOT backward-compatible with
previous software versions. The user is advised to save a copy of the pre-M.10.65 startup-config file
BEFORE UPDATING to M.10.68 or greater, in case there is ever a need to revert back to an earlier version
of software.
ProCurve Switch M.08.51 through
M.08.95
M.08.99.x
and newer
M.08.96, M.08.97,
M.10.01
and newer
ProCurve Switch 3400cl-24G (J4905A)
ProCurve Switch 3400cl-48G (J4906A)
ProCurve Switch 6400cl-6XG 10-GbE CX4(J8433A)
ProCurve Switch 6410cl-6XG 10-GbE X2(J8474A)
Zobrazit stránku 0
1 2 3 4 5 6 ... 196 197

Shrnutí obsahu

Strany 1 - Version M.10.72 Software

iRelease Notes: Version M.10.72 Softwarefor the HP ProCurve Series 3400cl Switches"M” software versions are supported on these switches:Relea

Strany 2 - http://www.openssl.org

xRelease M.10.42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 3 - Contents

90 EnhancementsRelease M.10.10 EnhancementsThe show spanning-tree command has also been extended to display BPDU filtered ports. Figure 24. Examp

Strany 4

91EnhancementsReleases M.10.11 through M.10.12 EnhancementsReleases M.10.11 through M.10.12 EnhancementsSoftware fixes only, no new enhancements.R

Strany 5

92 EnhancementsRelease M.10.17 EnhancementsFigure 27. Example of BPDU Protection Enabled at the Network EdgeTerminologyBPDU — Acronym for bridge

Strany 6

93EnhancementsRelease M.10.17 EnhancementsSTP — Spanning Tree Protocol, part of the original IEEE 802.1D specification. The 2004 edition completel

Strany 7

94 EnhancementsRelease M.10.17 EnhancementsViewing BPDU Protection StatusThe show spanning-tree command has additional information on BPDU protecti

Strany 8

95EnhancementsRelease M.10.21 EnhancementsRelease M.10.21 EnhancementsSoftware fixes only, no new enhancements.Release M.10.22 EnhancementsRelease

Strany 9

96 EnhancementsRelease M.10.22 EnhancementsTo display information about ports with loop protection, enter this command.Figure 28. Example of Show

Strany 10

97EnhancementsRelease M.10.23 EnhancementsRelease M.10.23 EnhancementsRelease M.10.23 includes the following enhancement: Enhancement (PR_1000379

Strany 11 - Software Management

98 EnhancementsRelease M.10.27 EnhancementsRelease M.10.27 EnhancementsRelease M.10.27 includes the following enhancement: Enhancement (PR_1000374

Strany 12

99EnhancementsRelease M.10.27 EnhancementsNotes: The aaa port-access controlled-direction in command allows Wake-on-LAN traffic to be transmitted

Strany 13 - TFTP Download from a Server

1Software ManagementSoftware UpdatesSoftware ManagementSoftware UpdatesCheck the ProCurve Networking Web site frequently for free software updates

Strany 14 - Send button

100 EnhancementsRelease M.10.28 EnhancementsRelease M.10.28 EnhancementsSoftware fixes only, no new enhancements.Release M.10.29 EnhancementsReleas

Strany 15

101EnhancementsRelease M.10.32 Enhancements The <hash-type> parameter specifies the type of algorithm (if any) used to hash the password. V

Strany 16

102 EnhancementsRelease M.10.33 Enhancements To schedule a reload in 3 hours:ProCurve# reload after 03:00 To schedule a reload for the same time th

Strany 17

103EnhancementsRelease M.10.33 Enhancements The port is temporarily assigned as a member of an untagged (static or dynamic) VLAN for use during t

Strany 18

104 EnhancementsRelease M.10.33 EnhancementsWhen the authentication session ends, the switch removes the temporary untagged VLAN assignment and re-

Strany 19

105EnhancementsRelease M.10.33 EnhancementsFigure 8. Example of an Active VLAN ConfigurationIn Figure Figure 8, if RADIUS authorizes an 802.1X cli

Strany 20 - Enforcing Switch Security

106 EnhancementsRelease M.10.33 EnhancementsFigure 10. Active Configuration for VLAN 33 Temporarily Drops Port 22 for the 802.1X SessionWhen the 80

Strany 21 - Secure File Transfers

107EnhancementsRelease M.10.33 EnhancementsEnabling the Use of GVRP-Learned Dynamic VLANs in Authentication SessionsSyntax: aaa port-access gvrp-v

Strany 22

108 EnhancementsRelease M.10.34 EnhancementsRelease M.10.34 EnhancementsRelease M.10.34 includes the following enhancement: Enhancement (PR_100041

Strany 23 - Physical Access to the Switch

109EnhancementsRelease M.10.35 EnhancementsRelease M.10.35 EnhancementsRelease M.10.35 includes the following enhancement: Enhancement (PR_100041

Strany 24

2 Software ManagementDownloading Software to the SwitchNoteDownloading new software does not change the current switch configuration. The switch co

Strany 25 - Network Access Security

110 EnhancementsRelease M.10.35 Enhancements• If a binding is invalid, the switch drops the packet, preventing other network devices from receiving

Strany 26 - Traffic/Security Filters

111EnhancementsRelease M.10.35 EnhancementsConfiguring Trusted PortsIn a similar way to DHCP snooping, dynamic ARP protection allows you to config

Strany 27 - 802.1X Access Control

112 EnhancementsRelease M.10.35 EnhancementsTo configure one or more Ethernet interfaces that handle VLAN traffic as trusted ports, enter the arp p

Strany 28

113EnhancementsRelease M.10.35 EnhancementsAn example of the ip source binding command is shown here:ProCurve(config)# ip source binding 0030c1-7f

Strany 29

114 EnhancementsRelease M.10.35 EnhancementsVerifying the Configuration of Dynamic ARP ProtectionTo display the current configuration of dynamic AR

Strany 30 - Clarifications and Updates

115EnhancementsRelease M.10.36 EnhancementsMonitoring Dynamic ARP ProtectionWhen dynamic ARP protection is enabled, you can monitor and troublesho

Strany 31 - IGMP Command Update

116 EnhancementsRelease M.10.37 EnhancementsConfiguring MSTP Port Connectivity ParametersWith release K.12.04, all ports are configured as auto-edg

Strany 32

117EnhancementsRelease M.10.37 Enhancements[root-guard]MSTP only. When a port is enabled as root-guard, it cannot be selected as the root port eve

Strany 33 - Rate-Limiting

118 EnhancementsRelease M.10.38 EnhancementsRelease M.10.38 EnhancementsRelease M.10.38 includes the following enhancement: Enhancement (PR_100042

Strany 34 - Known Issues

119EnhancementsRelease M.10.38 EnhancementsSend SNMP v2c InformsEnabling and Configuring SNMP InformsYou can use the snmp-server informs command (

Strany 35

3Software ManagementDownloading Software to the SwitchTFTP Download from a ServerSyntax: copy tftp flash <ip-address> <remote-os-file>

Strany 36 - Release M.08.79 Enhancements

120 EnhancementsRelease M.10.39 EnhancementsYou can see if informs are enabled or disabled with the show snmp-server command as shown in Figure 11.

Strany 37

121EnhancementsRelease M.10.39 Enhancements Enhancement (PR_1000428213) — This software enhancement adds the ability to configure a secondary aut

Strany 38 - Release M.08.89 Enhancements

122 EnhancementsRelease M.10.39 EnhancementsYou can configure local, chap-radius or eap-radius as the primary password authentication method for th

Strany 39 - Basic Operation

123EnhancementsRelease M.10.39 EnhancementsFigure 12. Example of AAA Authentication Using Authorized for the Secondary Authentication MethodSpec

Strany 40

124 EnhancementsRelease M.10.39 Enhancements Enhancement (PR_1000415155) — The ARP age timer was enhanced from the previous limit of 240 minutes t

Strany 41 - Configuring a DNS Entry

125EnhancementsRelease M.10.39 EnhancementsYou can also view the value of the Arp Age timer in the configuration file.Figure 15. Example Showing

Strany 42

126 EnhancementsRelease M.10.40 EnhancementsIf the ARP cache should become full because entries are not cleared (due to increased timeout limits) y

Strany 43

127EnhancementsRelease M.10.43 EnhancementsProtection Against IP Source Address SpoofingMany network attacks occur when an attacker injects packet

Strany 44

128 EnhancementsRelease M.10.43 EnhancementsPrerequisite: DHCP SnoopingDynamic IP lockdown requires that you enable DHCP snooping as a prerequisite

Strany 45 - Event Log Messages

129EnhancementsRelease M.10.43 EnhancementsIn this example, the following DHCP leases have been learned by DHCP snooping on port 5. VLANs 2 and 5

Strany 46 - Security Notes

4 Software ManagementDownloading Software to the Switch The terminal emulator you are using includes the Xmodem binary transfer feature. (For exam

Strany 47

130 EnhancementsRelease M.10.43 EnhancementsEnabling Dynamic IP LockdownTo enable dynamic IP lockdown on all ports or specified ports, enter the ip

Strany 48

131EnhancementsRelease M.10.43 Enhancements• Remove the trusted-port configuration. You can configure dynamic IP lockdown only from the CLI; thi

Strany 49 - QoS Pass-Through Mode

132 EnhancementsRelease M.10.43 EnhancementsAdding a Static BindingTo add the static configuration of an IP-to-MAC binding for a port to the lease

Strany 50

133EnhancementsRelease M.10.43 EnhancementsAn example of the show ip source-lockdown status command output is shown in Figure 20. Note that the op

Strany 51

134 EnhancementsRelease M.10.43 EnhancementsFigure 21. Example of show ip source-lockdown bindings Command OutputIn the show ip source-lockdown bin

Strany 52 - Release M.08.94 Enhancements

135EnhancementsRelease M.10.44 through M.10.64 EnhancementsFigure 22. Example of debug dynamic-ip-lockdown Command OutputRelease M.10.44 through M

Strany 53

136 EnhancementsRelease M.10.65 EnhancementsRelease M.10.65 EnhancementsRelease M.10.65 includes the following enhancement: Enhancement (PR_000000

Strany 54 - UDP Broadcast Forwarding

137EnhancementsRelease M.10.65 EnhancementsAll switches in a region must be configured with the same VLAN ID-to-MSTI mappings and the same MSTP co

Strany 55 - Release M.10.02 Enhancements

138 EnhancementsRelease M.10.65 EnhancementsEach MST instance supports a different set of VLANs. A VLAN that is mapped to an MST instance cannot be

Strany 56

139EnhancementsRelease M.10.65 EnhancementsFigure 23. Example of Mapping VLANs with the Range Option where all VLANs are IncludedNoteIf you want

Strany 57

5Software ManagementSaving Configurations While Using the CLISaving Configurations While Using the CLIThe switch operates with two configuration f

Strany 58

140 EnhancementsRelease M.10.66 Enhancements If you enter the spanning-tree instance vlan command before a static or dynamic VLAN is configured on

Strany 59 - General Operation

141EnhancementsRelease M.10.66 EnhancementsAdding a Description for a Syslog ServerYou can associate a user-friendly description with each of the

Strany 60 - The Packet-filtering Process

142 EnhancementsRelease M.10.66 EnhancementsFigure 30. Example of the Logging Command with a Priority DescriptionNoteA notification is sent to th

Strany 61

143EnhancementsRelease M.10.67 EnhancementsRelease M.10.67 EnhancementsSoftware fixes only, no new enhancements.Release M.10.68 EnhancementsReleas

Strany 62

144 EnhancementsRelease M.10.69 EnhancementshpSwitchLinkUpDownTrapAllPortsStatus OBJECT-TYPESYNTAX INTEGER {enable (1),disable (2) }ACCESS read-

Strany 63

145Software Fixes in Release M.08.51 - M.10.72Release M.08.52Software Fixes in Release M.08.51 - M.10.72Software fixes are listed in chronological

Strany 64 - Determining Traffic Policies

146 Software Fixes in Release M.08.51 - M.10.72Release M.08.612. In show CDP the Yes is changed to Yes,(Receive Only). CLI (PR_1000192677) — Show

Strany 65

147Software Fixes in Release M.08.51 - M.10.72Release M.08.62 Web UI (PR_1000177915) — Device View from the Web user interface is missing. Web

Strany 66

148 Software Fixes in Release M.08.51 - M.10.72Release M.08.64Release M.08.64Problems Resolved in Release M.08.64 (Not a general release) IP Routi

Strany 67 - Item Limit Notes

149Software Fixes in Release M.08.51 - M.10.72Release M.08.68Release M.08.68Problems Resolved in Release M.08.68 (Not a general release) Switchin

Strany 68 - ■ vendor and ACL identifiers:

6 Software ManagementInstall Recommendations for I.08.12 Boot ROM UpdateInstall Recommendations for I.08.12 Boot ROM UpdateWhen installing the M.1

Strany 69

150 Software Fixes in Release M.08.51 - M.10.72Release M.08.70 Port Security (PR_1000203984) — CLI port-security "mac-address" command w

Strany 70

151Software Fixes in Release M.08.51 - M.10.72Release M.08.72 LLDP (PR_1000241315) — CLI command "show LLDP" does not display informati

Strany 71

152 Software Fixes in Release M.08.51 - M.10.72Release M.08.75Release M.08.75Problems Resolved in Release M.08.75 LR optic (PR_1000282195) — Afte

Strany 72

153Software Fixes in Release M.08.51 - M.10.72Release M.08.78Release M.08.78Problems Resolved in Release M.08.78 (Not a general release) Enhancem

Strany 73

154 Software Fixes in Release M.08.51 - M.10.72Release M.08.83 RSTP (PR_1000300623) — Under some circumstances, the switch may allow packets to lo

Strany 74

155Software Fixes in Release M.08.51 - M.10.72Release M.08.87 SNMP (PR_1000295753) — Removing 'public' SNMP community generates an empt

Strany 75

156 Software Fixes in Release M.08.51 - M.10.72Release M.08.90• RADIUS Configuration via SNMP. For details refer to “Using SNMP To View and Configu

Strany 76

157Software Fixes in Release M.08.51 - M.10.72Release M.08.93Release M.08.93 Problems Resolved in Release M.08.93 (Not a general release) Help (P

Strany 77

158 Software Fixes in Release M.08.51 - M.10.72Release M.08.97Release M.08.97Problems Resolved in Release M.08.97 (Never released) OSPF (PR_100031

Strany 78 - SFlow Show Commands

159Software Fixes in Release M.08.51 - M.10.72Release M.10.04 sFlow (PR_1000321195)— A network management application may incorrectly report spik

Strany 79

7Software ManagementProCurve Switch, Routing Switch, and Router Software KeysProCurve Switch, Routing Switch, and Router Software KeysSoftware Let

Strany 80 - Release M.10.04 Enhancements

160 Software Fixes in Release M.08.51 - M.10.72Release M.10.07 Stacking (PR_1000311510) — When stacking is enabled, a stack member cannot be ‘ping

Strany 81

161Software Fixes in Release M.08.51 - M.10.72Release M.10.09Release M.10.09 Problems Resolved in Release M.10.09 CLI (PR_1000317554) — The show

Strany 82 - Known Limitations

162 Software Fixes in Release M.08.51 - M.10.72Release M.10.11Release M.10.11 Problems Resolved in Release M.10.11 Crash (PR_1000336436) — A “get/

Strany 83

163Software Fixes in Release M.08.51 - M.10.72Release M.10.14Release M.10.14 Problems Resolved in Release M.10.14 CLI (PR_1000342461) — Command “

Strany 84 - Examples

164 Software Fixes in Release M.08.51 - M.10.72Release M.10.17 DHCP Protection (PR_1000360273) — DHCP Lease renewal packets received on an untrust

Strany 85 - TCP/UDP Port Closure

165Software Fixes in Release M.08.51 - M.10.72Release M.10.21 Enhancement (PR_1000358900) — A RADIUS accounting enhancement was made. More inform

Strany 86 - Enabling/Disabling RIP

166 Software Fixes in Release M.08.51 - M.10.72Release M.10.23Release M.10.23 Problems Resolved in Release M.10.23 (Never released) Crash (PR_1000

Strany 87 - Spanning Tree Show Commands

167Software Fixes in Release M.08.51 - M.10.72Release M.10.26 STP/RSTP/MSTP (PR_1000386113) — In some cases STP/RSTP/MSTP may allow a loop on 10-

Strany 88

168 Software Fixes in Release M.08.51 - M.10.72Release M.10.28Release M.10.28 Problems Resolved in Release M.10.28 (Not a general release) CLI/LLD

Strany 89 - Release M.10.06 Enhancements

169Software Fixes in Release M.08.51 - M.10.72Release M.10.30 Transceiver hotswap (PR_1000390888) — Transceiver hotswap issues: • Simultaneous ho

Strany 90 - Release M.10.09 Enhancements

8 Software ManagementProCurve Switch, Routing Switch, and Router Software Keysnumeric Switch 9408sl, Switch 9300 Series (9304M, 9308M, and 9315M),

Strany 91

170 Software Fixes in Release M.08.51 - M.10.72Release M.10.32 RIP (PR_1000393366) — The switch does not process RIP (v2) responses containing sub

Strany 92 - Configuring UDLD

171Software Fixes in Release M.08.51 - M.10.72Release M.10.34 Crash (PR_1000407542) — Attempting to change the spanning-tree protocol version fro

Strany 93

172 Software Fixes in Release M.08.51 - M.10.72Release M.10.36 BPDU Protection (PR_1000395569) — BPDU-protection fails after module hot-swap. En

Strany 94 - Viewing UDLD Information

173Software Fixes in Release M.08.51 - M.10.72Release M.10.39Release M.10.39 Problems Resolved in Release M.10.39 Enhancement (PR_1000428213) —

Strany 95

174 Software Fixes in Release M.08.51 - M.10.72Release M.10.42 SCP (PR_1000428142) — The switch does not exit a secure copy protocol (SCP) session

Strany 96 - Port 4 is shown as blocked

175Software Fixes in Release M.08.51 - M.10.72Release M.10.45Release M.10.45Problems Resolved in Release M.10.45 (Not a Public Release) Web-UI (P

Strany 97

176 Software Fixes in Release M.08.51 - M.10.72Release M.10.48• The switch does not send an appropriate exit status message to the client. This cor

Strany 98 - Release M.10.10 Enhancements

177Software Fixes in Release M.08.51 - M.10.72Release M.10.50 through M.10.64Routed traffic is off by a factor of 1000Switched traffic is not samp

Strany 99

178 Software Fixes in Release M.08.51 - M.10.72Release M.10.66 Authentication (PR_1000454714) — Concurrent 802.1X and MAC Authentication does not

Strany 100

179Software Fixes in Release M.08.51 - M.10.72Release M.10.67 CLI (1000415243) — Output from the CLI command show name still lists 10-GbE trans-c

Strany 101 - Release M.10.17 Enhancements

9Software ManagementMinimum Software Versions for Series 3400cl Switch FeaturesMinimum Software Versions for Series 3400cl Switch FeaturesFor Soft

Strany 102 - Terminology

180 Software Fixes in Release M.08.51 - M.10.72Release M.10.68 Crash (PR_0000004023) — Repeated PCM configuration scans using SSH/SCP may cause th

Strany 103 - Enhancements

181Software Fixes in Release M.08.51 - M.10.72Release M.10.70 PC Phone/Authentication (PR_0000007209) — When an IP phone is used in tandem with a

Strany 104

182 Software Fixes in Release M.08.51 - M.10.72Release M.10.70 Dynamic ARP Protection (PR_0000009942) — When a switch using Dynamic ARP Protection

Strany 105 - Release M.10.22 Enhancements

183Software Fixes in Release M.08.51 - M.10.72Release M.10.71Release M.10.71Problems Resolved in Release M.10.71 (Not a Public Release) 802.1X (P

Strany 106

184 Software Fixes in Release M.08.51 - M.10.72Release M.10.72 Config (PR_0000005002) — If a friendly port name uses the characters TRUNK=, then a

Strany 107 - Release M.10.24 Enhancements

185Software Fixes in Release M.08.51 - M.10.72Release M.10.72Drop offer from <DHCP server IP address> of <DHCP address offer> because

Strany 108 - Release M.10.27 Enhancements

186 Software Fixes in Release M.08.51 - M.10.72Release M.10.72Message 2 (when an unauth-vid config is attempted on a port with an existing 802.1X u

Strany 109

© 2004 - 2009 Hewlett-Packard Development Company, LP. The information contained herein is subject to change without notice.October 2009Manual Part Nu

Strany 110 - Release M.10.31 Enhancements

© Copyright 2004 - 2009 Hewlett-Packard Development Company, LP. The information contained herein is subject to change without notice.Publication Nu

Strany 111 - Release M.10.32 Enhancements

10 Enforcing Switch SecuritySwitch Management Access SecurityEnforcing Switch SecurityProCurve switches are designed as “plug and play” devices, al

Strany 112 - Release M.10.33 Enhancements

11Enforcing Switch SecuritySwitch Management Access SecurityIt is important to evaluate the level of management access vulnerability existing in y

Strany 113 - Operating Notes

12 Enforcing Switch SecuritySwitch Management Access SecuritySNMP Access (Simple Network Management Protocol)In the default configuration, the swit

Strany 114

13Enforcing Switch SecuritySwitch Management Access SecurityCaution: Downloading and booting from the M.08.89 or greater software version for the

Strany 115

14 Enforcing Switch SecuritySwitch Management Access SecurityFor the commands to implement the above actions, refer to “Front-Panel Security” in th

Strany 116

15Enforcing Switch SecurityNetwork Access SecurityNetwork Access SecurityThis section outlines provisions for protecting access through the switch

Strany 117

16 Enforcing Switch SecurityNetwork Access SecuritySecure Shell (SSH)SSH provides Telnet-like functions through encrypted, authenticated transactio

Strany 118 - Release M.10.34 Enhancements

17Enforcing Switch SecurityNetwork Access Security source-port filters: Inbound traffic from a designated, physical source-port will be forwarded

Strany 119 - Release M.10.35 Enhancements

18 Enforcing Switch SecurityNetwork Access SecurityRefer to the chapter titled “Configuring Port-Based and Client-Based Access Control” in the Acce

Strany 120

19Enforcing Switch SecurityNetwork Access Securitykeys.) KMS provides specific instances of routing protocols with one or more Send or Accept keys

Strany 121 - Configuring Trusted Ports

iiiContentsSoftware Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Software Updates . . . . . . . .

Strany 122

20 Clarifications and UpdatesOperating Notes for Jumbo Traffic-HandlingClarifications and UpdatesOperating Notes for Jumbo Traffic-HandlingIn the M

Strany 123

21Clarifications and UpdatesIGMP Command UpdateIGMP Command UpdateThe following information updates and clarifies information in Chapter 4, “Multi

Strany 124

22 Clarifications and UpdatesGeneral Switch Traffic Security GuidelineSetting Fast-Leave and Forced Fast-Leave from the CLI. In earlier switch mode

Strany 125 - Release M.10.37 Enhancements

23Clarifications and UpdatesThe Management VLAN IP Address4. Port security5. Authorized IP Managers6. Application features at higher levels in the

Strany 126

24 Known IssuesRate-LimitingKnown IssuesRelease M.10.17The following is a known issue related to installation of Release M.10.17 software, which in

Strany 127

25EnhancementsRelease M.08.69 EnhancementsEnhancementsEnhancments are listed in chronological order, oldest to newest software release. To review

Strany 128 - Release M.10.38 Enhancements

26 EnhancementsRelease M.08.78 EnhancementsRelease M.08.78 EnhancementsUsing Fastboot To Reduce Boot TimeThe fastboot command allows a boot sequenc

Strany 129 - Send SNMP v2c Informs

27EnhancementsRelease M.08.80 through M.08.83 EnhancementsThe following shows a sample output from this new command.Figure 2. Example rate displ

Strany 130 - Release M.10.39 Enhancements

28 EnhancementsRelease M.08.84 EnhancementsRelease M.08.84 EnhancementsRelease M.08.84 includes the following enhancement:Added the show tech tran

Strany 131 - RADIUS Server Unavailable

29EnhancementsRelease M.08.89 EnhancementsIP address of 10.10.100.27 is assigned a host name of accounts015 and another IP address of 10.10.100.33

Strany 132

ivConnection-Rate Filtering Based On Virus-Throttling Technology . . . . . . . . . . . . . . . . . . . . . . . 19Identity-Driven Management (IDM) .

Strany 133

30 EnhancementsRelease M.08.89 Enhancements The host’s domain must be reachable from the switch. This requires that the DNS server for the switc

Strany 134 - ARP Age Timer Increase

31EnhancementsRelease M.08.89 EnhancementsConfiguring a DNS EntryThe switch allows one DNS server entry, which includes the DNS server IP address

Strany 135

32 EnhancementsRelease M.08.89 EnhancementsFigure 5. Example Network DomainConfiguring switch “A” with the domain name and the IP address of a DN

Strany 136 - Release M.10.43 Enhancements

33EnhancementsRelease M.08.89 EnhancementsFigure 7. Example of Ping and Traceroute Execution for the Network in Figure 5 on Page 32As mentioned

Strany 137

34 EnhancementsRelease M.08.89 EnhancementsFigure 9. Example of Viewing the Current DNS ConfigurationOperating Notes The DNS server must be acce

Strany 138

35EnhancementsRelease M.08.89 EnhancementsEvent Log MessagesUsing SNMP To View and Configure Switch Authentication Features In earlier software re

Strany 139

36 EnhancementsRelease M.08.89 EnhancementsSecurity NotesPasswords and keys configured in the hpSwitchAuth MIB are not returned via SNMP, and the r

Strany 140

37EnhancementsRelease M.08.89 EnhancementsFor example, to disable SNMP access to the switch’s authentication MIB and then display the result in th

Strany 141

38 EnhancementsReleases M.08.90 and M.08.91 EnhancementsFigure 11. Using the show run Command to View the Current Authentication MIB Access State

Strany 142 - Adding a Static Binding

39EnhancementsReleases M.08.90 and M.08.91 EnhancementsThe “legacy-path-cost” CLI command does not affect or replace functionality of the “spannin

Strany 143

vQoS Pass-Through Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Release

Strany 144

40 EnhancementsReleases M.08.90 and M.08.91 EnhancementsNoteChanging the QoS Pass-Through Mode can be done without rebooting the switch. However, t

Strany 145

41EnhancementsReleases M.08.90 and M.08.91 EnhancementsQoS Pass-Through Mode SNMP MIB Object. A read-write MIB object, 1.3.6.1.4.1.11.2.14.11.5.1.

Strany 146 - Release M.10.65 Enhancements

42 EnhancementsRelease M.08.94 EnhancementsThe current QoS Pass-Through Mode also is displayed in the show running-config command output.Operating

Strany 147 - Enabling MSTP on the Switch

43EnhancementsRelease M.08.94 EnhancementsExampleIn the routing switch shown below, option 82 has been configured with mgmt-vlan for the Remote ID

Strany 148

44 EnhancementsRelease M.08.94 EnhancementsTable 3. DHCP Operation for the Topology in Figure 12Operating Notes Routing is not allowed between t

Strany 149

45EnhancementsReleases M.08.95 through M.10.01 EnhancementsReleases M.08.95 through M.10.01 EnhancementsSoftware fixes only; no new enhancements.R

Strany 150 - Release M.10.66 Enhancements

46 EnhancementsRelease M.10.02 Enhancements An ACL must be configured on the RADIUS server (instead of the switch) by creating and assigning one o

Strany 151 - Adding a Priority Description

47EnhancementsRelease M.10.02 EnhancementsTable 4. Contrasting Dynamic and Static ACLsRADIUS-Based (Dynamic) ACLs Port-Based (Static) ACLsOpera

Strany 152 - Switches

48 EnhancementsRelease M.10.02 EnhancementsTerminologyACE: See Access Control Entry, below.Access Control Entry (ACE): An ACE is a policy consistin

Strany 153 - Release M.10.68 Enhancements

49EnhancementsRelease M.10.02 Enhancementspacket (from the authenticated client) that is not explicitly permitted or denied by other ACEs configur

Strany 154 - Release M.10.72 Enhancements

viRelease M.10.26 Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Rele

Strany 155 - Release M.08.61

50 EnhancementsRelease M.10.02 Enhancementsthe client MAC address is the selection criteria, only the client having that MAC address can use the co

Strany 156

51EnhancementsRelease M.10.02 EnhancementsExample. Suppose the ACL in Figure 3 is assigned to filter the traffic from an authenticated client on a

Strany 157 - Release M.08.63

52 EnhancementsRelease M.10.02 Enhancements Figure 4. The Packet-Filtering Process in an ACL with N Entries (ACEs)NoteThe order in which an ACE occ

Strany 158 - Release M.08.67

53EnhancementsRelease M.10.02 EnhancementsFor example, suppose you want to configure a RADIUS-based ACL to invoke these policies in the 11.11.11.0

Strany 159 - Release M.08.69

54 EnhancementsRelease M.10.02 EnhancementsGeneral StepsThese steps suggest a process for using ACLs to establish client access policies. The topic

Strany 160 - Release M.08.71

55EnhancementsRelease M.10.02 Enhancements Is it important to keep track of the number of matches for a particular client or ACE? If so, you can

Strany 161 - Release M.08.74

56 EnhancementsRelease M.10.02 Enhancements Explicitly Denying Any IP Traffic: Entering a deny in ip from any to any ACE in an ACL denies all IP t

Strany 162 - Release M.08.77

57EnhancementsRelease M.10.02 EnhancementsLimits for RADIUS-Based ACLs, Associated ACEs, and Counters Table 5 describes limits the switch supports

Strany 163 - Release M.08.82

58 EnhancementsRelease M.10.02 EnhancementsConfiguring an ACL in a RADIUS ServerThis section provides general guidelines for configuring a RADIUS s

Strany 164 - Release M.08.86

59EnhancementsRelease M.10.02 EnhancementsFigure 6. Example of Configuring the VSA for RADIUS-Based ACLs in a FreeRADIUS Server2. Enter the switc

Strany 165 - Release M.08.89

viiRelease M.10.65 Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136MST

Strany 166 - Release M.08.92

60 EnhancementsRelease M.10.02 EnhancementsFigure 8. Example of Configuring the FreeRADIUS Server To Support ACLs for the Indicated ClientsFormat

Strany 167 - Release M.08.96

61EnhancementsRelease M.10.02 EnhancementsThe following syntax and operating information refers to ACLs configured in a RADIUS server.ACE Syntax:

Strany 168 - Release M.10.03

62 EnhancementsRelease M.10.02 EnhancementsConfiguring the Switch To Support RADIUS-Based ACLsAn ACL configured in a RADIUS server is identified by

Strany 169 - Release M.10.06

63EnhancementsRelease M.10.02 Enhancements3. Configure an authentication method. Options include 802.1X, Web authentication, and MAC authenticatio

Strany 170 - Release M.10.08

64 EnhancementsRelease M.10.02 EnhancementsDisplaying the Current RADIUS-Based ACL Activity on the SwitchThese commands output data indicating the

Strany 171 - Release M.10.10

65EnhancementsRelease M.10.02 EnhancementsSyntax: show port-access authenticator < port-list >For ports,in < port-list > that are conf

Strany 172 - Release M.10.12

66 EnhancementsRelease M.10.02 EnhancementsFigure 10. Example of Output Showing Current RADIUS-Applied Features Event Log MessagesMessage Meaning

Strany 173 - Release M.10.16

67EnhancementsRelease M.10.02 EnhancementsCauses of Client Deauthentication Immediately After Authenticating ACE formatted incorrectly in the RAD

Strany 174 - Release M.10.20

68 EnhancementsRelease M.10.02 Enhancements• An ACE in the ACL for a given authenticated client exceeds 80 characters.• An ACL assigned to an authe

Strany 175 - Release M.10.22

69EnhancementsRelease M.10.02 EnhancementsFigure 13. Viewing sFlow Agent InformationThe show sflow destination command includes information abou

Strany 176 - Release M.10.25

viiiRelease M.08.76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 177 - Release M.10.27

70 EnhancementsRelease M.10.04 Enhancements Figure 15. Example of Viewing sFlow Sampling and Polling InformationThe show sflow all command combin

Strany 178 - Release M.10.29

71EnhancementsRelease M.10.04 EnhancementsOperating Notes To generate alerts for monitored events, you must enable the instrumentation monitoring

Strany 179 - Release M.10.31

72 EnhancementsRelease M.10.04 Enhancements Alerts are automatically rate limited to prevent filling the log file with redundant information. The

Strany 180 - Release M.10.33

73EnhancementsRelease M.10.04 EnhancementsConfiguring Instrumentation MonitorThe following commands and parameters are used to configure the opera

Strany 181 - Release M.10.35

74 EnhancementsRelease M.10.04 EnhancementsExamplesTo turn on monitoring and event log messaging with the default medium values: ProCurve(config)#

Strany 182 - Release M.10.38

75EnhancementsRelease M.10.04 EnhancementsFigure 18. Viewing the Instrumentation Monitor ConfigurationTCP/UDP Port Closure In earlier software r

Strany 183 - Release M.10.41

76 EnhancementsRelease M.10.04 EnhancementsEnabling/Disabling TFTPThe TFTP server and client can be enabled and/or disabled independently.Enabling/

Strany 184 - Release M.10.44

77EnhancementsRelease M.10.04 EnhancementsNoteThe router rip command exists in previous software versions. In this implementation, however, RIP mu

Strany 185 - Release M.10.47

78 EnhancementsRelease M.10.04 EnhancementsThe following shows RSTP sample output from the enhanced command. Figure 19. Example of Show Spanning

Strany 186 - Release M.10.49

79EnhancementsRelease M.10.05 Enhancements• TC Flag Received counter shows the number of TC notifications (RSTP or MSTP style BPDU with the TC fla

Strany 187 - Release M.10.65

ixRelease M.10.10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 188 - Release M.10.66

80 EnhancementsRelease M.10.07 EnhancementsRelease M.10.07 EnhancementsRelease M.10.07 includes the following enhancement: Added support for PIM D

Strany 189 - Release M.10.67

81EnhancementsRelease M.10.09 EnhancementsFigure 20. UDLD ExampleSimilarly, UDLD is effective for monitoring fiber optic links that use two uni-

Strany 190 - Release M.10.69

82 EnhancementsRelease M.10.09 EnhancementsConfiguration Considerations UDLD is configured on a per-port basis and must be enabled at both ends of

Strany 191 - Release M.10.70

83EnhancementsRelease M.10.09 EnhancementsEnabling UDLD. UDLD is enabled on a per port basis. For example, to enable UDLD on port a1, enter:To en

Strany 192 - = 0x85cc1eb0

84 EnhancementsRelease M.10.09 EnhancementsNotes You must configure the same VLANs that will be used for UDLD on all devices across the network; o

Strany 193 - Release M.10.72

85EnhancementsRelease M.10.09 EnhancementsDisplaying Summary UDLD Information. To display summary information on all UDLD-enabled ports, enter the

Strany 194 - RADIUS server is unavailable

86 EnhancementsRelease M.10.09 EnhancementsDisplaying Detailed UDLDP Status Information. To display detailed UDLD information for specific ports, e

Strany 195

87EnhancementsRelease M.10.09 EnhancementsConfiguration Warnings and Event Log MessagesWarning Messages. The following table shows the warning mes

Strany 196

88 EnhancementsRelease M.10.10 EnhancementsRelease M.10.10 EnhancementsRelease M.10.10 includes the following enhancement:Spanning Tree Per-Port BP

Strany 197

89EnhancementsRelease M.10.10 EnhancementsCautionPorts configured with the BPDU filter mode remain active (learning and forward frames); however,

Komentáře k této Příručce

Žádné komentáře