HP 2000i G2 Modular Smart Array User Guide 51
Is the drive enclosure Fault/Service Required LED amber?
Answer Possible Reasons Actions
No System functioning properly. No action required.
Yes
(blinking)
One of the following errors
occurred:
Hardware-controlled
power-up error
Cache flush error
Cache self-refresh error
Check the event log for specific information regarding
the fault.
Isolate the fault.
Contact an authorized service provider for assistance.
Replace if necessary.
Yes A fault occurred.
If installing an I/O module
FRU, the module has not gone
online and likely failed its
self-test.
Check the event log for specific information regarding
the fault.
Isolate the fault.
Contact an authorized service provider for assistance.
Replace if necessary.
If installing an I/O module FRU, try removing and
reinstalling the new I/O module, and check the event
log for errors.