436 HSG80 Users Guide
Tachyon Status
The number that appears in the Tachyon Status field represents the
current state of the Tachyon, or Fibre Channel control chip. It consists
of a two-digit hex number, the first of which is explained in Figure
412. The second digit is outlined in Figure 413. Refer to the Tachyon
users manual for a more detailed explanation of the Tachyon
definitions.
Table 412 Tachyon First Digit
State Definition State Definition
0 MONITORING 8 INITIALIZING
1 ARBITRATING 9 O_I INIT FINISH
2 ARBITRATION WON A O_I PROTOCOL
3 OPEN B O_I LIP RECEIVED
4 OPENED C HOST CONTROL
5 XMITTED CL0SE D LOOP FAIL
6 RECEIVED CLOSE F OLD PORT
7 TRANSFER
Table 413 Tachyon Second Digit
State Definition State Definition
0OFFLINE 6LR2
1OL1 7LR3
2OL2 9LF1
3OL3 ALF2
5 LR1 F ACTI VE