Using Logs
171Director Element Manager User Guide
Each log entry includes the following:
■ Date/Time—The date and time of the event on the director
■ Event—Events are identified by a unique code. Event codes include:
The following acronyms may display in this column for the port card:
— GLSL—G_Port, long wave, single-mode LC connector, 1 Gigabit
— GSML—G_Port, short wave, multi-mode, LC connector, 1 Gigabit
— GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
— FPM—G_Port, small form factor pluggable (SFP) optics, FICON port
module, 1 Gigabit
— UPM—G_Port, small form factor pluggable (SFP) optics, universal port
module, 2 Gigabit
— GSF2—G_Port, small form factor pluggable (SFP) optics, universal port
module, 2 Gigabit
— GLSR—G_Port, short wave, single-mode, MT-RJ connector, 1 Gigabit
— GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
— GSMR—G_Port, short wave, multi-mode, MT-RJ connector, 1 Gigabit
The chassis (slot) position for a non-redundant FRU is 0. The chassis
positions for redundant FRUs are 0, 1, and 2. The chassis positions for port
cards are 0 through 35, and slot 32 is unavailable.
■ Description—A short description of the event
Table 5: Event codes
Code Event
000–199 System events
200–299 Power supply events
300–399 Fan module events
400–499 CTP card events
500–599 Port card events
600–699 SBAR card events
800–899 Thermal events