Appendix B Download Commands 119
Appendix B
Multi-frame sequences are allowed. Transfer length for each write must be less
than or equal to 64KB (65536 bytes).
It is required that the parameter list length be the same as the FCP_DL field in
the FCP_CMND IU.
Report LUNs Command
In SCC mode, the Interface Manager supports the FC report LUNs command.
The report LUNs command will return a list of logical unit numbers that can
receive commands. The format of the report LUNs command is as follows:
Table 5 Report LUNs Command
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (0xA0)
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
(MSB)
Allocation Length
(LSB)
7
8
9
10
Reserved
11
Control Byte
Komentáře k této Příručce