Strany 1 - Generation 3 drives

HP Ultrium drivesTechnical reference manualGeneration 3 drivesVolume 4: SpecificationsPart Number: Q1530–90901 Volume 4Edition 5, December 2004

Strany 2

Physical specification102 Physical specificationDimensionsDetailed dimensionsFigure 1-1 PlanSCSI Fibre ChannelInternal width: 146 mm (5.75") 146

Strany 3 - Contents

11Figure 1-2 SideWith Fiber Channel, the connector stands out at the back of the drive:Figure 1-3 Fibre Channel connectorFigure 1-4 Front[No drawing a

Strany 4 - 4Contents

Physical specification12Figure 1-5 Rear View—SCSIFigure 1-6 Rear view—Fibre ChannelProduct weight*including front panel and ESD bag but excluding rail

Strany 5 - Related documents

133 Electrical requirementsPSU requirementsInternal and rack-mounted drivesThe drives are specified to operate at 5V±5% and 12V±10%. Any PSU used to p

Strany 6 - Interface

Electrical requirements14Read24.3W 30.8W TBDReposition/Rewind24.4W 31.6W TBDUnload16.8W 28.2W TBDSCSI Drives FC DrivesActivity Average Peak Average

Strany 7 - Ultrium features

154 Electromagnetic compatibilityNOTE: The EMC performance of internal storage products depends on the characteristics of the system in which the prod

Strany 8

Electromagnetic compatibility16DC magnetic field interference• IATA Dangerous Goods Regulations, 30th Edition, 1989-01-01• U.S. CFR 49, paragraph 173.

Strany 9 - 1Features

175EnvironmentalClimaticsThese apply to the mechanism unless otherwise noted. For the environmental specification of media, see Chapter 7, “Media”.Ope

Strany 10 - 2 Physical specification

Environmental18DynamicsNoiseAirflowHP Ultrium drives require forced airflow from front to back.Parameter SpecificationOperating sine vibration 0.31G p

Strany 11 - Figure 1-4 Front

196SafetySafety regulatory standardsRequired agency approvalsTransceiversThe Fibre Optic transceivers used in FC products are Class 1 Laser components

Strany 12 - Drive orientation

2Notice© Copyright 2001–2004 Hewlett-Packard Development Company L.P.The information contained in this document is subject to change without notice.He

Strany 13 - 3 Electrical requirements

Media207MediaSpecification*Capacities at 2:1 data compression. The actual capacity depends on the compression ratio of the data. This is typically 2:1

Strany 14 - 16.8W 28.2W TBD

21Environmental specifications (media)OperatingStorage (day-to-day)Storage (transportation)Storage (archival)Cartridges should be stored in plastic co

Strany 15 - ITE immunities

Media22Interface specification• Contactless, passive RF interface using a proximity inductive coupling with a range in the order of millimeters.• Powe

Strany 16

238 Ultrium format standardCompatibilityHP Gen 3 Ultrium drives are specified to interchange data cartridges with other tape drives that comply to the

Strany 17 - 5Environmental

Reliability249ReliabilityDescription SpecificationMTBF (100% duty cycle) 250,000 hoursLoad/unload life 100,000 swapsMSBF (automation swaps) 100,000 sw

Strany 18 - Dynamics

2510 Performance specificationTransfer ratesThe bandwidth of the data compression engine determines the drive’s streaming capabilities based on the co

Strany 19 - Transceivers

Performance specification26TimingsCapacity full backup timesThe following table shows approximate backup times for the available tape cartridges:Load/

Strany 20 - Specification

2711 Automation Control InterfaceSpecificationPhysical interface• RS-422, Drive Sense, Library Sense, Reset and Attention signals• A default of 9600 b

Strany 21 - LTO-Cartridge Memory (EEPROM)

Automation Control Interface28

Strany 22 - Further information

IndexIndex 29Aaccess time 26ACI 27agency approvals 19airflow 18altitude 17ANSI 5archival storageenvironment 21automation control interface 27B

Strany 23 - 8 Ultrium format standard

ContentsContents 3Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Doc

Strany 25 - 10 Performance specification

4Contents7MediaSpecification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Environmental

Strany 26 - Other times

Related documents 5Related documentsThe following documents provide additional information: Documents specific to HP Ultrium drives• Hardware Integrat

Strany 27

6OperationCartridgesInterfaceMaintenance and troubleshootingSCSI Drives FC DrivesExternal drives (SCSI only) 1 HW Integration: ch. 5n/aIn Libraries 1

Strany 28

Related documents 7Dealing with errorsUltrium featuresGeneral documents and standardization• Enhanced Small Computer System Interface (SCSI-2), ANSI X

Strany 29 - Index 29

8• See http://www.t10.org/t10_main.htm for ANSI SCSI-3 and other specificationsCopies of documents of other standards bodies can be obtained from: ANS

Strany 30

91FeaturesFeature SpecificationRecording format Linear Tape Open Ultrium-3 and Ultrium-2.Ultrium-1 tapes can be read but not written.Data compression