Table 15 30-10010-02 loop switch port status indicators
DescriptionPort bypass indicator
(Amber)
SFP status
indicator (Green)
Indicates that the port does not have an SFP installed and is bypassed
by the loop.
OffOff
Indicates that the port is operating normally. The port and device are
fully operational.
OffOn
Indicates the that port is in a bypassed state. The port is non-operational
due to loss of signal, poor signal integrity, or the Loop Initialization
Procedure (LIP).
NOTE: This condition is also normal when the SFP is present but not
attached to a Fibre Channel drive enclosure node, or when the SFP is
present and attached to only a cable assembly. Attaching the SFP to a
device and plugging it into the port should initiate the LIP by the attached
device.
OnOn
Indicates a Tx fault. The port is non-operational due to an SFP transmitter
fault, improperly-seated SFP, or another failed device.
OnOff
Problem isolation
Table 16 (page 41) lists several basic problems and their solutions.
Table 16 30-10010-02 loop switch basic troubleshooting
Recommended actionProblem
SFPs are installed in ports but no indicators
are lit.
1. Verify that the power cord is firmly seated in the switch and is
connected to the power outlet.
2. Check the power indicator to verify that the switch is on.
Re-seat the SFP. If the same condition occurs, the SFP is probably faulty
and should be replaced.
SFP is installed, but the Port Bypassed
indicator is lit.
This condition indicates that the switch is not receiving a valid Fibre
Channel signal or that the switch is receiving an LIP.
SFP is installed, but the SFP status indicator
and the Port Bypassed indicator are lit.
1. Ensure that the switch is powered on.
2. Contact your HP authorized service representative for further
assistance.
This condition indicates that the switch is receiving a valid Fibre Channel
signal, but there are no upper level protocols active.
SFP is installed and the SFP status indicator
is lit, but the devices are not communicating.
1. Verify that you are running the correct firmware on all storage system
hardware.
2. Check the Loop Operational indicator.
a. If the Loop Operational indicator is lit, the devices have completed
initialization.
b. If the Loop Operational indicator is off, the devices were not
initialized. Disconnect the devices from the switch. Reconnect the
devices one at a time. This allows you to isolate the device that
is responsible for the loop failure.
3. Contact your authorized service representative for further assistance.
HSV controllers
Two controllers (HSV210-A/B or HSV200-A/B) are contained in each rack. Each controller is
contained in a separate controller and provides the following features:
High-performance microprocessor
An Operator Control Panel (OCP)
HSV controllers 41
Zobrazit stránku 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 179 180

Komentáře k této Příručce

Žádné komentáře

Asg-jergens 66104 EZ-3080 Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Ausrüstung Asg-jergens 66104 EZ-3080.
Wir stellen 1 PDF-Handbücher Asg-jergens 66104 EZ-3080 zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Ausrüstung Asg-jergens

Modelle Dokumententyp
ASG-SD2500-35PL-SY-NC Bedienungsanleitung   ASG Jergens ASG-SD2500-35PL-SY-NC User Manual, 2 Seiten
66137 EZ-9000RP Bedienungsanleitung   ASG Jergens 66137 EZ-9000RP User Manual, 2 Seiten
68416 Filter/Regulator Bedienungsanleitung   ASG Jergens 68416 Filter/Regulator User Manual, 1 Seiten
66102 EZ-3000 Bedienungsanleitung   ASG Jergens 66102 EZ-3000 User Manual, 2 Seiten
67241 NSB-12 NSB Bedienungsanleitung   ASG Jergens 67241 NSB-12 NSB User Manual, 2 Seiten
65006 Tool Support Stands Bedienungsanleitung   ASG Jergens 65006 Tool Support Stands User Manual, 1 Seiten
65060 Pneumatically-Assisted Articulating Torque A Bedienungsanleitung   ASG Jergens 65060 Pneumatically-Assisted Articulating Torque Arm User Manual, 2 Seiten
66134 EZ-870 Bedienungsanleitung   ASG Jergens 66134 EZ-870 User Manual, 2 Seiten
ASG-SD2500-50RP-SY Bedienungsanleitung   ASG Jergens ASG-SD2500-50RP-SY User Manual, 2 Seiten
ASG-SD2500-35RP-SY Bedienungsanleitung   ASG Jergens ASG-SD2500-35RP-SY User Manual, 2 Seiten
64033 HM-10 Bedienungsanleitung   ASG Jergens 64033 HM-10 User Manual, 2 Seiten
67402 NJL-2323 Bedienungsanleitung   ASG Jergens 67402 NJL-2323 User Manual, 2 Seiten
67346 Optional Rail Assembly for NJL- Series Bedienungsanleitung   ASG Jergens 67346 Optional Rail Assembly for NJL- Series User Manual, 1 Seiten
ASG-SD2500-10PS-SY-NC Bedienungsanleitung   ASG Jergens ASG-SD2500-10PS-SY-NC User Manual, 2 Seiten
ASG-SD2500-35PS-SY-NC Bedienungsanleitung   ASG Jergens ASG-SD2500-35PS-SY-NC User Manual, 2 Seiten
66106 EZ-3150 Bedienungsanleitung   ASG Jergens 66106 EZ-3150 User Manual [en] [de] [fr] , 2 Seiten
64011 HP-10 Bedienungsanleitung   ASG Jergens 64011 HP-10 User Manual, 2 Seiten
ASG-SD2500-10PL-SY Bedienungsanleitung   ASG Jergens ASG-SD2500-10PL-SY User Manual, 2 Seiten
65046 Articulating Torque Arm Bedienungsanleitung   ASG Jergens 65046 Articulating Torque Arm User Manual, 2 Seiten
67327 Optional Rail Assembly for Quicher NSB & Bedienungsanleitung   ASG Jergens 67327 Optional Rail Assembly for Quicher NSB & NJ-Series User Manual, 1 Seiten