ARM
The ARM subsystem selects the number of scanning cycles (1 through
32767) for each
INITiate command.
ARM
:COUNt <
number
>
MIN | MAX
:COUNt? [MIN | MAX]
:COUNt ARM:COUNt <number> MIN | MAX allows scanning cycles to occur a
multiple of times (1 to 32767) with one
INITiate command when
INITiate:CONTinuous OFF | 0 is set. MIN sets 1 cycle and MAX sets 32,767
cycles.
Parameters
Parameter Name Parameter Type Range of Values Default Value
number
numeric 1 - 32767 | MIN | MAX 1
Comments Number of Scans: Use only numeric values between 1 and 32767
for the number of scanning cycles (default is 1).
Related Commands: ABORt, INITiate:IMMediate
*RST Condition: ARM:COUNt 1
Example Setting Ten Scanning Cycles
This example sets a Microwave Switch for 10 scans of channels 00 through
02. When the scan sequence completes, channels 00 through 02 (switches
00 through 02) are closed.
ARM:COUN 10 Set 10 scans per INIT command.
SCAN (@100:102) Scan channels 00-02.
INIT Start scan, close channel 00.
Chapter 4 HP E1368A/69A/70A Command Reference 51