Field direct con
nect—HP StorageWorks EVA or EVA4400 iSCSI connectivity
option with direct connect at tachment mode
Figure 1 illustrates the direct connect iSCSI–Fibre Channel attachment mode conguration.
NOTE:
This option is supported only on the EVA4400 running XCS 9.000 or later rmware, or
EVA4 x0 0/6x00/8x00 running XCS 5.100 or later rm ware.
To install eld direct connect with direct connect attachment mode:
1.
Rack mount the mpx100/100b. (See Rack mount the mpx100/100b”onpage43.)
2. Connect one end of the black Fibre Channel cable into the FC1 port of the mpx100/100b
(Figure 1 on page 22).
3. Connect the other end of the black Fibre Channel cable into an available FP port of the HSV top
controller.
4. Connect one end of the black Fibre Channel cable into the FC2 port of the mpx100/100b
(Figure 1 on page 22).
5. Connect the other end of the black Fibre Channel cable into an available FP port of the HSV
bottom controller.
6. Install supplied p ort loopback connects on any unused HSV controller host ports.
7. Set the HSV controller ports to direct connect topology:
NOTE:
For the EVA4400, see the product installation documentation.
a. Press the Down Arrow key on the EVA front panel. System Information is displayed.
b. Press the Right Arrow key. Versions is displayed.
c. Press the Down Arrow key. Host Port Config is displayed.
d. Press the Right Arrow key. Fabric is displayed.
e. Press the Down Arrow key. Direct Connect is d isplayed.
f. Press the Right Arrow key. Port 1 is displayed.
g. Press the Down Arrow key until the port that you want to change to Direct Connect
Mode is displayed.
h. Press Enter.
i. Repeat the process for the other controller.
8. Continue w ith Connect the mpx10 0/10 0b to an IP switch on page 44.
Field fabric attach—HP StorageWorks EVA or EVA4400 iSCSI connectivity
option with fabric at tach mode
Figur
e7on p age 27 illustrates the fabric iSCSI–Fibre Channel attachment mode conguration.
To ins
tall the iSCSI connectivity option with fabric attachment mode:
1.
Rack mount the mpx100/100b. (See Rack mount the mpx100/100b”onpage43.)
2. Install SFPs in the mpx100/100b ports ( FC1, FC2) and the top and bottom controller FP ports.
3. Connect one end of the orange Fibre Channel c able to the FC1 SFP por t of the mpx100/100b.
Connect the other end of the orange Fibre Channel cable to any available SFP port on the
Fib
re Channel switch.
42
Installing and upgrading EVA iSCSI connectivity