Cause. The firmware revision field of an SCC FIR or the switch card FIR string read
from the switch module is not present or is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The firmware revision field header of an SCC FIR or the switch card FIR string
read from the switch module is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. An SCC FIR or the switch card FIR string read from the switch module did not
terminate with the correct end-of-FIR token.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
***PROTOCOL ERROR*** Bad firmware revision field in SCC/SC
FIR string.”
***PROTOCOL ERROR*** Bad firmware revision header in SCC/SC
FIR string.
***PROTOCOL ERROR*** Bad end-of-FIR token in SCC/SC FIR
string.