Hp ProLiant DL360 G6 Server Uživatelský manuál Strana 33

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 127
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 32
Hardware options installation 33
Hardware options installation
Introduction
If more than one option is being installed, read the installation instructions for all the hardware options and
identify similar steps to streamline the installation process.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause electrostatic discharge.
Processor and fan module option
Install fan 2 only when processor 2 is installed. When only one processor is installed, always install the fan
blank.
To install the component:
1. Update the system ROM.
Locate and download the latest ROM version from the HP website (http://www.hp.com/support).
Follow the instructions on the website to update the system ROM.
2. Power down the server (on page 19).
3. Extend the server from the rack (on page 19).
4. Remove the access panel (on page 21).
5. Remove the BBWC battery pack (on page 21).
6. Remove the air baffle (on page 22).
Zobrazit stránku 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 126 127

Komentáře k této Příručce

Žádné komentáře