HP ProLiant DL585 G7 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 617692-004
October 2012
Edition: 4
Zobrazit stránku 0
1 2 3 4 5 6 ... 125 126

Shrnutí obsahu

Strany 1 - User Guide

HP ProLiant DL585 G7 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage sys

Strany 2

Component identification 10 Rear panel components Item Description Item Description 1 Power supply bay 4 (optional) 15 Expansion slot

Strany 3 - Contents

Battery replacement 100 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the ba

Strany 4 - Contents 4

Regulatory compliance notices 101 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory complianc

Strany 5 - Contents 5

Regulatory compliance notices 102 radio communications. However, there is no guarantee that interference will not occur in a particular installation

Strany 6 - Contents 6

Regulatory compliance notices 103 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Strany 7 - Component identification

Regulatory compliance notices 104 This symbol on the product or on its packaging indicates that this product must not be disposed of with your oth

Strany 8 - Front panel LEDs and buttons

Regulatory compliance notices 105 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optic

Strany 9 - Systems Insight Display

Regulatory compliance notices 106 Batteries, battery packs, and accumulators should not be disposed of together with the general household waste.

Strany 10 - Rear panel components

Regulatory compliance notices 107 WARNING: Exposure to Radio Frequency Radiation—The radiated output power of this device is below the FCC radio f

Strany 11 - Rear panel LEDs and buttons

Regulatory compliance notices 108 Taiwan notices

Strany 12 - Power supply LED

Electrostatic discharge 109 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions y

Strany 13 - System board components

Component identification 11 Rear panel LEDs and buttons Item Description LED color Status 1 iLO 3 NIC Activity LED Green On or flashing—Ne

Strany 14 - System maintenance switch

Specifications 110 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shi

Strany 15 - SPI board components

Support and other resources 111 Support and other resources Before you contact HP Be sure to have the following information available before you cal

Strany 16

Support and other resources 112 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strany 17 - DIMM slot locations

Support and other resources 113 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'i

Strany 18 - Device numbers

Support and other resources 114 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen

Strany 19 - SAS hard drive LEDs

Support and other resources 115 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strany 20 - Battery pack LEDs

Support and other resources 116 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pe

Strany 21

Support and other resources 117

Strany 22 - FBWC module LEDs

Support and other resources 118

Strany 23 - Fan locations

Acronyms and abbreviations 119 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility AMP Ad

Strany 24 - Item Description

Component identification 12 Power supply LED Power LED Status Off No AC power to power supply units Green AC is present. Standby outpu

Strany 25 - Operations

Acronyms and abbreviations 120 KVM keyboard, video, and mouse NUMA Non-Uniform Memory Architecture NVRAM nonvolatile memory ORCA Option ROM Confi

Strany 26 - Remove the access panel

Acronyms and abbreviations 121 SIM Systems Insight Manager SPI system peripheral interface TMRA recommended ambient operating temperature TPM Tru

Strany 27 - Install the access panel

Documentation feedback 122 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documenta

Strany 28 - Remove the SPI board

Index 123 1 10 Gb NIC adapter blank 10 A access panel 26, 27 acoustics statement for Germany 106 ACU (Array Configuration Utility) 75 additi

Strany 29

Index 124 European Union notice 103 expansion board 16 expansion boards 54, 57, 59 expansion boards, non-hot-plug 54 expansion boards, shipp

Strany 30 - Optimum environment

Index 125 mouse connector 10, 15 N NIC adapter blank 10 NIC connectors 10, 15 NVRAM, clearing 14 O online spare memory 44, 74 online spare

Strany 31 - Temperature requirements

Index 126 server fault indications flowchart 96 server features and options 35 server options, installing 33, 35 server specifications 110 s

Strany 32 - Rack warnings

Component identification 13 System board components Item Description 1 Optional I/O expansion board connectors: • PCI-X/PCI Express I/O ex

Strany 33 - Installing hardware options

Component identification 14 System maintenance switch The system maintenance switch (SW5) is an ten-position switch that is used for system config

Strany 34 - Registering the server

Component identification 15 SPI board components Item Description 1 Mini-SAS connectors (2) 2 SAS cache connector 3 TPM connector 4 Fan data c

Strany 35 - Introduction

Component identification 16 I/O expansion board components • PCI-X/PCI Express I/O expansion board Item Description 1 Slot 6 PCIe2 x16 (16, 8

Strany 36

Component identification 17 Item Description 5 Slot 2 PCIe2 x8 (8, 4, 2, 1) 6 Slot 1 PCIe1 x8 (8, 4, 2, 1) DIMM slot locations • Primary proces

Strany 37 - Processor options

Component identification 18 • Secondary processor memory board Device numbers

Strany 38

Component identification 19 SAS hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS hard drive LED comb

Strany 39

© Copyright 2010, 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strany 40

Component identification 20 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Off Steadily amber A critical fault condition has

Strany 41

Component identification 21 LED3 pattern LED4 pattern Interpretation Off Flashing (2 Hz) The system is powered down, and the cache contains

Strany 42

Component identification 22 FBWC module LEDs The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse sid

Strany 43 - Memory configurations

Component identification 23 Fan locations Power supply backplane components

Strany 44 - Population guidelines

Component identification 24 Item Description 1 Graphics card power connector 2 Graphics card power connector 3 Graphics card power connector 4

Strany 45 - Memory bus speed

Operations 25 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server WARNING: To reduc

Strany 46 - DIMM identification

Operations 26 2. Extend the server on the rack rails until the server rail-release latches engage. 3. After performing the installation or maint

Strany 47 - Advanced ECC memory

Operations 27 2. Extend the server from the rack (on page 25). 3. Open the locking latch, slide the access panel to the rear of the chassis, and re

Strany 48 - Install the DIMMs

Operations 28 5. Firmly holding the processor memory drawer, press the release buttons and then remove the drawer from the server. Access the Syst

Strany 49

Operations 29 3. Remove the access panel (on page 26). 4. Disconnect all cables from the SPI board. IMPORTANT: If replacing the SPI board or cl

Strany 50 - Hot-plug hard drive option

Contents 3 Contents Component identification ...

Strany 51

Setup 30 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Strany 52

Setup 31 Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when decid

Strany 53

Setup 32 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of

Strany 54 - Expansion board options

Setup 33 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor.

Strany 55

Setup 34 To configure these utilities manually: • Press the F8 key when prompted during the array controller initialization to configure the array

Strany 56

Hardware options installation 35 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strany 57

Hardware options installation 36 4. Remove the tray with the I/O enabler board. CAUTION: When installing the tray with the secondary processor

Strany 58

Hardware options installation 37 Processor options The server supports up to four processors. Observe the following processor installation guideline

Strany 59

Hardware options installation 38 4. Remove the processor memory drawer cover. 5. If not installed, install the secondary processor memory board (&

Strany 60

Hardware options installation 39 7. Open the processor socket retaining bracket and the processor locking lever. IMPORTANT: Be sure the process

Strany 61

Contents 4 Introduction ...

Strany 62

Hardware options installation 40 9. The processor fits one way into the socket. Use the alignment guides on the processor and socket to properly ali

Strany 63

Hardware options installation 41 12. Remove the thermal interface media protective cover. CAUTION: To avoid possible mechanical or thermal

Strany 64

Hardware options installation 42 13. Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly. 14. Re

Strany 65

Hardware options installation 43 For detailed DIMM population guidelines, see "Memory configurations (on page 43)." 17. Install the DIMM

Strany 66

Hardware options installation 44 Population order A I E C K G Processor memory channel A A A B B B Processor memory socket 7 8 9 10

Strany 67

Hardware options installation 45 When Online Spare memory is enabled, one of the ranks is set aside as the Online spare rank. In the event that rank

Strany 68

Hardware options installation 46 DR 1066 MHz 3 — 3 mixed SR 1333 MHz DR 1333 MHz DR 1066 MHz 1066 MHz 800 MHz 3 1 2 SR 1333 MHz DR 1333 MHz DR

Strany 69

Hardware options installation 47 Item Description Definition 1 Size — 2 Rank 1R = Single-rank 2R = Dual-rank 4R = Quad-rank 3 Data width x

Strany 70

Hardware options installation 48 4. Remove the tray. 5. Remove the DIMM baffle. 6. Install the DIMMs.

Strany 71 - Cabling

Hardware options installation 49 For configuration options, see "Memory configurations (on page 43)." 7. Install the DIMM baffle. CAU

Strany 72 - Configuration tools

Contents 5 Keeping the system current ...

Strany 73 - Auto-configuration process

Hardware options installation 50 4. Remove the DIMM baffle. 5. Install the DIMMs. For configuration options, see "Memory configurations (on p

Strany 74 - Configuring AMP modes

Hardware options installation 51 • The system automatically sets all device numbers. • If only one hard drive is used, install it in the bay with

Strany 75 - Array Configuration Utility

Hardware options installation 52 3. Install the hard drive. 4. Determine the status of the drive from the hot-plug SAS hard drive LED combinations

Strany 76 - Management tools

Hardware options installation 53 2. Slide the power supply into the power supply bay until the device locks into place. 3. Connect the power cord

Strany 77 - Erase Utility

Hardware options installation 54 The cable and the cable arrangement might appear differently from shown. 7. Install the SPI board. 8. Install th

Strany 78 - USB support

Hardware options installation 55 4. Open the expansion board retainer, and then remove the expansion slot cover. 5. Install the expansion board.

Strany 79 - Diagnostic tools

Hardware options installation 56 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all expansion slots hav

Strany 80 - Keeping the system current

Hardware options installation 57 6. Install the shipping screw. 7. Close the expansion slot retainer. 8. Install the access panel (on page 27). 9

Strany 81 - HP Smart Update Manager

Hardware options installation 58 4. Release the latches on the release lever. 5. Lower the handle, and then extend the processor memory drawer fro

Strany 82 - Care Pack

Hardware options installation 59 6. Install the PCI Express I/O expansion board. 7. Install any expansion boards ("Installing an expansion bo

Strany 83 - Troubleshooting

Contents 6 Taiwan notices ...

Strany 84 - Warnings and cautions

Hardware options installation 60 4. Release the latches on the release lever. 5. Lower the handle, and then extend the processor memory drawer fro

Strany 85 - Symptom information

Hardware options installation 61 6. Install the PCI-X/PCI Express I/O expansion board. 7. Install any expansion boards ("Installing an expans

Strany 86 - Loose connections

Hardware options installation 62 6. Install the mini-DIMM on the SPI board. 7. Install the SPI board. 8. Using a T-15 Torx screwdriver, remove th

Strany 87 - Troubleshooting flowcharts

Hardware options installation 63 10. Secure the 10G NIC connectors to the chassis with the retaining screw. 11. Install the RJ-45 plugs on the bot

Strany 88 - General diagnosis flowchart

Hardware options installation 64 The BBWC consists of two parts: a battery pack and a storage cache module. Along with the cache module, the battery

Strany 89

Hardware options installation 65 6. Attach the cable to the cache module. 7. Install the battery. 8. Connect the cable to the battery. The SPI bo

Strany 90 - Symptoms:

Hardware options installation 66 CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMM pinout. Do not use the cont

Strany 91

Hardware options installation 67 8. Connect the cable. 9. Install the capacitor pack. 10. Install the SPI board. 11. Install the access panel (

Strany 92 - Troubleshooting 92

Hardware options installation 68 TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker Drive Enc

Strany 93 - POST problems flowchart

Hardware options installation 69 3. Extend the server from the rack (on page 25). 4. Remove the SPI board (on page 28). 5. Locate the TPM connecto

Strany 94

Component identification 7 Component identification Front panel components Item Description 1 Serial and PID tag 2 Optical drive 3 Systems Ins

Strany 95 - OS boot problems flowchart

Hardware options installation 70 Enabling the Trusted Platform Module 1. When prompted during the start-up sequence, access RBSU by pressing the F9

Strany 96 - Troubleshooting 96

Cabling 71 Cabling DVD-ROM drive cabling

Strany 97 - • Redundancy failure

Server software and configuration utilities 72 Server software and configuration utilities Configuration tools SmartStart software SmartStart is a c

Strany 98 - (http://www.hp.com/support)

Server software and configuration utilities 73 • Displaying system information • Selecting the primary boot controller • Configuring memory optio

Strany 99 - Troubleshooting 99

Server software and configuration utilities 74 By default, the auto-configuration process configures the system for the English language. To change

Strany 100 - Battery replacement

Server software and configuration utilities 75 Configuring online spare memory To configure online spare memory: 1. Install the required DIMMs. 2.

Strany 101 - FCC rating label

Server software and configuration utilities 76 • Reconfiguring one or more logical drives • Viewing the current logical drive configuration • Del

Strany 102 - Modifications

Server software and configuration utilities 77 operating system is functioning properly, the system periodically resets the timer. However, when the

Strany 103 - • EMC Directive 2004/108/EC

Server software and configuration utilities 78 CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to i

Strany 104 - BSMI notice

Server software and configuration utilities 79 Diagnostic tools HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool,

Strany 105 - Battery replacement notice

Component identification 8 Front panel LEDs and buttons Item Description Status 1 UID button and LED Blue—Activated Blue (flashing)—Server be

Strany 106 - Wireless devices

Server software and configuration utilities 80 Remote support and analysis tools HP Insight Remote Support software HP strongly recommends that you

Strany 107 - Japanese notices

Server software and configuration utilities 81 For example: http://www.hp.com/support/dl360g6 (http://www.hp.com/support/dl360g6) Version control T

Strany 108 - Taiwan notices

Server software and configuration utilities 82 HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers

Strany 109 - Electrostatic discharge

Troubleshooting 83 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Strany 110 - Specifications

Troubleshooting 84 Symbols on equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous condition

Strany 111 - Support and other resources

Troubleshooting 85 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The

Strany 112

Troubleshooting 86 2. Record any error messages displayed by the system. 3. Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys. 4. Power

Strany 113 - Customer Self Repair

Troubleshooting 87 Service notifications To view the latest service notifications, refer to the HP website (http://www.hp.com/go/bizsupport). Select

Strany 114

Troubleshooting 88 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure o

Strany 115 - Reparo feito pelo cliente

Troubleshooting 89 Item See 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Doc

Strany 116

Component identification 9 Systems Insight Display The Systems Insight Display LEDs represent the server and component layout. LED Description

Strany 117

Troubleshooting 90 Server power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Strany 118

Troubleshooting 91 • The external health LED is red or amber. • The internal health LED is red or amber. NOTE: For the location of server LED

Strany 120

Troubleshooting 93 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system att

Strany 121

Troubleshooting 94 Item See 13 • "Server information you need" in the HP ProLiant Servers Troubleshooting Guide located on the Documenta

Strany 122 - Documentation feedback

Troubleshooting 95 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Smar

Strany 123 - Index 123

Troubleshooting 96 Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents • Ser

Strany 124 - Index 124

Troubleshooting 97 Possible causes: • Improperly seated or faulty internal or external component • Unsupported component installed • Redundancy f

Strany 125 - Index 125

Troubleshooting 98 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in th

Strany 126 - Index 126

Troubleshooting 99 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before re

Komentáře k této Příručce