HP Insight Management Agents
User Guide
Part number: 308447-005 a
Fifth edition: June 2009
Zobrazit stránku 0
1 2 3 4 5 6 ... 97 98

Shrnutí obsahu

Strany 1 - HP Insight Management Agents

HP Insight Management Agents User Guide Part number: 308447-005 aFifth edition: June 2009

Strany 2

NOTE: If you have enabled anonymous access, then you can access the System Management Homepage displays without asking for any credentials locally

Strany 3 - Contents

Header frame The header frame is always visible regardless of which tab you are viewing. A link, located in the top section, displays the path you ar

Strany 4 - Contents 4

Host Name Displays full computer name of the system. System model The System Model displays the model of the device. In some cases, the System Model

Strany 5 - Browser requirements

Refresh Click on the Refresh link to refresh the System Management Homepage. . Body frame The body of the window displays the status for a

Strany 6 - Obtaining JVM from Sun

System Status The System Status window displays an icon for the overall status of the system. The system status is determined by the status of the

Strany 7

• Logical Disks • Processors • Server • Memory • Network • Physical Disks • Processes • Processor Utilization Storage The Storage window disp

Strany 8 - Overview

SNMP Webagent The HP Management Agents page is used to view and set the HP Management Agents configuration. It allows settings for Server

Strany 9 - Logging in

Management HTTP Server section The Management HTTP Server section provides links allowing you to configure your Management HTTP

Strany 10 - System Management Homepage

System Management Homepage. Some web applications restrict viewing of critical information from individuals with User access. • Local Server Certif

Strany 11 - Header frame

Tasks Tab The Tasks tab displays links to task-oriented pages provided by participating HP Web-Enabled System Management software. NOTE: If the HP W

Strany 12

Legal notices © Copyright 2002, 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. T

Strany 13 - Home tab

Support tab The Support tab contains of links to available support services like – ProLiant Essential Software Info, Integrity Essential

Strany 14

2 Agent information Management Host agent The Management Host agent gathers data for the HP Host OS MIB. This data includes: • Server/host name and O

Strany 15 - Settings tab

System Agent Software version information The software version section displays the versions of the system software installed on this machine: BIOS,

Strany 16 - SNMP Webagent

• Client/Internal—The network is used to connect client systems and for internal cluster communication. • None—The network is not used by the cluste

Strany 17 - Security

• Orring Diode Failed • Brownout • Give Up On Startup • NVRAM Invalid • Calibration Table Invalid • If the power supply is absent, the status i

Strany 18 - UI Properties

NOTE: A Failed condition does not occur in a client PC since the power supply for the client is cut off if thermal condition reaches a permanently d

Strany 19 - Webapps tab

• Disabled—ECC memory correction is supported, but errors are not logged for this device. • When a certain rate of errors is exceeded the health dr

Strany 20 - Help tab

• Mirroring—This system is configured for Mirrored Memory Protection. All memory banks are duplicated in Mirrored Memory, as opposed to only one for

Strany 21 - 2 Agent information

• Other—Memory type can not be determined. • Board—The value determine the memory module is permanently mounted (not modular) on a system board or

Strany 22 - System Agent

Management Processor Integrated Lights-Out (iLO) NIC The NIC section displays the following information about the NIC in the iLO. Not all fields are s

Strany 23 - Sub system Classification

Contents 1 HP Insight Management Agents for Servers…………………………………………………………………………5 Browser requirements ...

Strany 24 - Cooling and temperature

• Pending Alarm—Displays if the alert is unable to determine the state of the iLO, or if all alerts have been delivered or if there are alerts pendi

Strany 25 - Agent information 25

Self Test Results The Self Test Results section indicates various error-status depending on the Remote Insight model. The following is the list of er

Strany 26 - Agent information 26

Select Reset to Original Values to return to the original threshold values, or the values from the last time the thresholds were saved. This option a

Strany 27 - Memory Details

interrupts and DPCs. A high rate of privileged time might be attributable to many interrupts generated by a failing device. This counter displays the

Strany 28 - PCI Devices

• Context Block Queue/sec—Rate per second at which the work context blocks must be placed on the FSP queue of the server to await server action. •

Strany 29 - Management Processor

Nonpaged Bytes, so it might not equal Process: Pool Nonpaged Bytes: _Total. This counter displays the last observed value only; it is not an average.

Strany 30 - Modem/COM Port Settings

• Page Faults/sec—Rate at which the page faults occur in the executing threads within this process. A page fault occurs when a thread refers to a vi

Strany 31 - Operating System

• Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in the controller firmware and the operating sys

Strany 32 - Logical Disk Space

• High—Indicates the rebuild priority is high. • Unknown—Indicates that the rebuild priority is not recognized. You may need to upgrade the Storage

Strany 33 - Server

temporarily suspended until the batteries are fully charged. Array accelerator operations automatically resume when charging is complete. • Degraded—

Strany 34 - Agent information 34

3 Subsystem specific to a NetWare operating system………………………………………………………………79 Operating system overview ...

Strany 35 - Processes

• POST ECC Errors—Indicates that write cache operations have been permanently disabled. The cache has been disabled due to a large number of ECC err

Strany 36 - Processor Utilization

Physical Drive Information This section provides an overview of all disk drives attached to the controller. Each physical drive is listed as a separ

Strany 37 - Agent information 37

• Current Speed—Displays the current negotiated data transfer rate for a SCSI physical drive. The possible values are: • Asynchronous—The negotiat

Strany 38 - Agent information 38

• Status—Indicates the status of the data path. Possible values are: • OK—The path is operational. • Link down—The path is not operational. • U

Strany 39 - Agent information 39

Predictive Indicators Use the Predictive Indicators to predict when a drive, which is now operating normally, may need to be replaced. • S.M.A.R.T.

Strany 40 - Identify Drives

IMPORTANT: Never turn off a storage system when the attached system is still turned on. • Check the physical proximity of the system to other elec

Strany 41 - Physical Drive Information

• Reallocation Aborts—When the physical drive is failed due to an error that occurred when the controller was trying to reallocate a bad sector, a R

Strany 42 - Agent information 42

• Hard Read Errors—Displays the number of read errors that could not be recovered by a physical drive's Error Correction Code (ECC) algorithm or

Strany 43 - Logical Drive Information

• Shutdown—Indicates that the drive array enclosure that contains the logical drive has overheated. The logical drive is no longer functioning. • E

Strany 44 - Problem Indicators

• RAID 50—Distributed data guarding (RAID 5) with multiple parity groups. • RAID 60—Advanced data guarding (RAID 6) with multiple parity groups. •

Strany 45 - Failure Indicators

1 HP Insight Management Agents for Servers The HP System Management Homepage version 8.25 and later acts as the Web server for the Management Agents.

Strany 46 - Statistics

• Serial Number—Displays the unit serial number for the tape library. Use this value for identification purposes. • Protocol Type—Displays the prot

Strany 47

• Missing - Was Offline —Indicates that a tape drive that was located in a system and had a status of offline has been removed. • Unknown—Indicates

Strany 48 - Agent information 48

• Tape Errors—Displays the total number of read and write errors encountered. This value is maintained from the moment the Tape Hardware Interface d

Strany 49 - Identify Drive

• Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The following values are possible: • OK—The fan subsystem is w

Strany 50 - Tape Drive Information

• Path—Indicates the path to the storage system. Each path is identified by a descriptor. For example, "Port 2E Box 1" indicates a path fr

Strany 51 - Agent information 51

the channel, then “Channel unknown” displays. If the device position cannot be determined, then “Device unknown” displays and driver software or the S

Strany 52 - Storage Systems

• Rebuilding—Indicates that the logical drive is rebuilding a physical drive. When complete, the logical drive returns to normal operation. • Faile

Strany 53 - Agent information 53

• Compaq 32-Bit Fast-Wide SCSI-2/E Controller • Compaq 32-Bit Fast-Wide SCSI-2/P Controller • Compaq Wide-Ultra SCSI Controller • Compaq Wide-Ultr

Strany 54 - IDE ATA disk drives

• Power Drive CD-ROM—A storage device that can read from a CD and write to or read from an optical disk. • CR3500 RAID Controller—A three-channel S

Strany 55 - IDE ATA logical drives

• Not supported—Indicates that the library cannot detect or report redundancy status. • Unknown—The redundancy status of the tape library cannot be

Strany 56 - Controller information

Obtaining JVM from Microsoft Java support for Internet Explorer can be downloaded from Microsoft at http://www.microsoft.com/java/sdk, where the JVM

Strany 57 - SCSI device information

• Model—Displays a description of the SCSI tape autoloader media changer model as returned by the SCSI inquiry command. • Firmware Version—Displays

Strany 58 - Tape library

• Vendor—Displays the vendor name for the CD Library. This item can be used for identification purposes. • Model—Displays the model name of the CD L

Strany 59 - Tape devices

• Duplex Top—This storage system is the top part of a duplexed unit. • Duplex Bottom—This storage system is the bottom part of a duplexed unit. •

Strany 60 - CD Library Information

• Available—This drive supports predictive failure monitoring. • Unknown—The Storage Agents cannot determine if the drive supports predictive failur

Strany 61 - CD-ROM drive information

• Failure Indicator—Use this utility to determine the cause of failure for a failed drive. If the drive has failed and this counter is non-zero, rep

Strany 62 - SCSI physical drives

SCSI logical drives Select a SCSI logical drive from the SCSI controller submenu to display the following information. The following values are valid:

Strany 63 - Drive indicators

Spare drives A list of spare drives that can be used by this logical drive to replace a failed drive. Select one of the listed spare drives to see mo

Strany 64 - Drive statistics

NOTE: If the current data transfer width is Narrow (8 bits) then the speed in megabytes per second is equal to the million transfers per second spee

Strany 65 - SCSI logical drives

Use the ASR Reset Limit feature in conjunction with the ASR Reset Count feature in the same window. The ASR Reset Count feature displays the number o

Strany 66 - SCSI bus information

• Serial Number—Displays the Physical serial number of the device or client system board. Use this number for identification and registration purpose

Strany 67 - System Configuration

After you enter the URL, the System Management Homepage appears. Security The HP Insight Management Agents allow SNMP sets for some system parameters

Strany 68 - System Board

• Other—The system does not support Advanced Memory Protection or the Management Agent cannot determine the status. • Not Protected—This system sup

Strany 69 - Advanced Memory Protection

• Advanced Memory Protection Condition—displays the current condition of the Advanced Memory Protection subsystem. The following states are supported

Strany 70 - Agent information 70

• FPM (Fast-Page Mode) • EDO (Extended Data Out) • BEDO (Burst Extended Data Out) • Synch DRAM (Synchronous DRAM) • Unknown System Resources T

Strany 71 - General I/O Devices

• Monitor Serial Number displays the serial number for the monitor. Use this number for identification purposes. • Monitor Manufacture Date displays

Strany 72 - System Summery

• Enclosure Model • Asset Tag • Part Number • Spare Pat Number • Serial Number • Firmware Revision • Previous Enclosure Name • Next Enclosure

Strany 73 - Enclosure Information

Namespace: root\default Object Class: CPQ_System_Performance Subclasses: • CPQ_System • ContextSwitchRate • CpqQueueLength • Processes • Registry

Strany 74 - Agent information 74

• DiskWriteBytesPersec • DiskWritesPersec • PhysicalDisk • CPQ_LogicalDisk • DiskQueueLength • DiskTimePercent • FreeMegabytes • FreeSpacePer

Strany 75 - Agent information 75

IMPORTANT: To mark entries as corrected, the agents must have sets enabled and the SNMP Community string must be correct. The following list descri

Strany 76 - Critical Error Log

• Server Manager Failure—An error occurred in the server interface with the Server Manager. • UPS A/C Line Failure/Shutdown or Battery Low—The devi

Strany 77 - Agent information 77

3 Subsystem specific to a NetWare operating system Operating system overview HP now provides operating system management for NetWare environments. The

Strany 78 - Integrated Management Log

• The WEBAGENT.INI file is located in the directory /var/opt/CPQIMddd/web/im/webagent if the pathname is /var/opt/CPQIMddd/bin/cpqthresh_mib, where

Strany 79 - Summary page

File System page The File System page provides the file system information for the server. The page is divided into the following three sections: •

Strany 80 - User Information page

General information The General Information section displays the following information: • User Count—The number of entries in the User Account Table.

Strany 81 - Loaded NLMs page

• Memory (bytes) (sortable)—The total memory, in bytes, used by the NLM. This value is a composite of Short Term Memory, Semi-Permanent Memory, and

Strany 82 - Physical Partition page

• InwDos • Other • Description (sortable)—A brief description of this partition. • Size (sortable)—The size (in Kilobytes) of this physical partit

Strany 83 - Adapter Information page

4 CR3500 RAID Array SCSI controller Mass storage RAID Array This section displays RAID array information. Five banners appear in this section. RAID a

Strany 84 - Mass Storage Physical

• Formatting—The drive is currently being formatted. • Action—Provides a brief description of an action you can take depending on the physical drive

Strany 85 - Environment Monitoring Unit

• Critical—The controller temperature sensor has detected a critical temperature condition in the primary enclosure. • Non-critical—The controller

Strany 86 - External Expansion Cabinet

5 Where to go for additional help In addition to this guide, the following information sources are available: • HP Insight Management Agents 7.30 Inst

Strany 87 - Telephone numbers

Appendix A Troubleshooting Insight Management Agents for Servers issues Inability to perform remote reboot on a server from the Management Console 1.

Strany 88 - Appendix A Troubleshooting

When attempting to browse to Web-Enabled System Management software on port 2381, the system is not accessible because of an invalid password This iss

Strany 89

administrators if the file system enables it. For private key security reasons, HP recommends that the Management HTTP Server be installed on Windows

Strany 90 - issues

d. Click Reset>OK. • There are known browser issues in the Management Agents for Tru64 UNIX. However, many have been corrected in later releases

Strany 91 - Insight Manager issues

4. Click OK. When prompted to restart the Management Agents, click Yes. Insight Manager cannot manage a system If the Microsoft® SNMP service was ins

Strany 92

NOTE: The HP Diagnostics utility initializes physical drives attached to HP Drive Arrays. Disk Subsystem button disabled in the Disk Storage windo

Strany 93 - Other problems

The HP Foundation Agents service could not terminate agent "CPQMHOST." The data contains the error code. The HP Foundation Agents service co

Strany 94

System restart to disk-based utilities fails for NetWare If you click Reboot on the Insight Manager display, and select the option to boot to the dis

Strany 95 - Glossary

Glossary Automatic Server Recovery (ASR)A server feature designed to automatically restart the server after a critical hardware or software error. If

Strany 96 - Glossary 96

Simple Network Management Protocol (SNMP)SNMP defines a set of commands that a management application uses to retrieve or change the values of items

Strany 97

Index A accounts, user, 8 Adapter Information Page, 83 array controllers, 84 ASR POST failure, 93 B browser, 89 browser requirements, 5 C Client data

Strany 98

software, cluster, 23 spare drives: RAID Array, 84 subsystem button, disabled, 92 Summary Page, 79 System Management Homepage, 9, 11 system restart p