Hp ProLiant DL760 Server Uživatelský manuál Strana 134

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 229
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 133
Installing Hardware Options - Hot Pluggable 5-31
Compaq Confidential Need to Know Required
Writer: Bryce Miller Project: Compaq ProLiant DL760 Servers User Guide Comments:
Part Number: 173774-001 File Name: f-ch5 Installing Hardware Options - Hot Pluggable.doc Last Saved On: 1/18/01 6:12 PM
Replacing Hot-Plug Fans
The ProLiant DL760 server ships with two hot-plug fans. Fan 1 is closest to
the rear of the server. Each fan has LED indicators that indicate the status of
the fan as follows:
No lightpower is not applied to the fan
Green light power is applied to the fan and the fan is functional
Amber light the fan has failed
21
Figure 5-17. Hot-plug fan LED indicators
CAUTION: Never remove both hot-plug fans while the server is powered up.
Overheating and damage to hardware could result. If the appropriate Compaq
software drivers are installed, the operating system software will initiate a
power shutdown in the event of overheating.
NOTE: The hot-plug fan LED indicators are not part of the fan housing. Figure 5-17
shows the LED indicators as if the fan were installed in the server.