HP Proliant ML350 Generation 3 Instalační příručka Strana 153

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 197
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 152
C
Server Error Messages
The following POST error message is new and unique to some HP ProLiant servers:
A processor thermal event occurred prior to this power
up, Processor X
This message indicates that processor X (1 or 2) has reached an excessive
temperature and has stopped operation. Verify the following information:
The processor and heatsink assembly is properly installed. ·
· Ambient temperature is within an acceptable range.
Refer to Appendix F, “Specifications,” for operational temperature
requirements.
For a complete listing of error messages provided for the server, refer to the Servers
Troubleshooting Guide in your user documentation.
HP ProLiant ML350 Generation 3 Server Setup and Installation Guide C-1
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: i-appc Server Error Messages.doc
Codename: Steel Venom Part Number: 316354-001 Last Saved On: 12/9/02 8:36 AM
Zobrazit stránku 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 196 197

Komentáře k této Příručce

Žádné komentáře