Programming 15-33
Nmin / Nmax
6HTXHQFH
Defines the minimum and maximum independent variable
values. Appears as the NRNG fields in the Plot Setup input
form.
From Plot Setup, enter values for NRNG.
or
In a program, type
&Nmin
&Nmax
where
Recenter
$OO$SOHWV
Recenters at the crosshairs locations when zooming.
From Plot-Zoom-Set Factors, check (or uncheck)
Recenter
or
In a program, type
1 & Recenter— to turn recenter on (default).
0 & Recenter—to turn recenter off.
Root
)XQFWLRQ
Contains the last value found by the Root function in the
Plot-FCN menu.
S1mark–S5mark
6WDWLVWLFV
Defines the mark to use for statistics 2-variable scatter plots.
From Plot Setup for two-variable statistics, S1mark-
S5mark, then choose a mark.
or
In a program, type
n & S1mark
where n is 1,2,3,...5
SeqPlot
6HTXHQFH
Toggles type of sequence plot: Stairstep or Cobweb.
From Plot Setup, select SeqPlot, then choose Stairstep
or Cobweb.
or
In a program, type
1 &SeqPlot—for stairstep.
2 &SeqPlotfor cobweb.
n
1
n
2
n
2