Power Over Ethernet (PoE) Operation
Configuring PoE Operation
1. Use the walkmib pethPsePortType.< slot-# > command to determine the MIB-
based port number for the port to which you want to assign a Configured
Type identifier. On the 5300xl switches the slot numbering is as follows:
Slot Slot Number
Used in the MIB
A
B
C
D
E*
F*
G*
H*
*5308xl only.
Note that in the MIB, 26 port numbers are assigned to each slot designa-
tion. Thus, for example, with PoE modules in slots “A” and “B”, the actual,
corresponding port numbers will be 1-24 and 27-50, respectively. (The port
numbers “25, “26”, “51, and “52” are reserved.)
2. Use the setmib pethPsePortType.< slot-# >.< port-# > -D < identifier-string >
command to configure the identifier you want for a specific port.
For example, suppose that you have a PoE xl Module installed in slot B and
want to assign the identifier “Wireless-1” to port 1 in this slot. To do so, you
would use the following commands: