Hp Insight Cluster Management Utility Uživatelský manuál Strana 107

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 191
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 106
active node list selected: o185i192
Please read /opt/cmu/log/PowerOff.log for errors.
cmu>
Setting the locator LED on or off
Sets the locator LED of any number of nodes on or off. You can use the regular expressions
previously described.
cmu> Locate on|off cmu_nodes_regular_expression
For example:
cmu> locate on o185i192
active node list selected: o185i192
cmu>
For example:
cmu> locate off o185i192
active node list selected: o185i192
cmu>
Cloning a set of nodes
Clones an image to a node or a set of nodes. You can use all the regular expressions previously
described. After cloning, successfully cloned nodes are active in the logical group associated with
the image. Failed nodes are active in the logical group “default”.
cmu> clone "image_name" cmu_nodes_regular_expression
For example:
cmu> clone "cluster " o185i195
active node list selected: o185i195
node list found in backup group cluster: o185i195
Save /opt/cmu/log/cmucerbere.log file
Cleaning boot directory
Configuring the system
[INFO] CMU does not seem to be running
Copying the ssh settings
Rebuilding network-boot image
/opt/cmu/tmp/GUI/config.txt was rewritten
Starting cloning
Every 2.0s: /opt/cmu/tools/logAnalyser.sh
Cloning started on 2006-08-08 at [17:07:55]
+----------------------------------+----------+
| NET BOOTING | |
+----------------------------------+----------+
| PARTITION & FORMAT DISKS | |
+----------------------------------+----------+
| GETTING DATA | |
+----------------------------------+----------+
| CLONING ERROR | |
+----------------------------------+----------+
| CLONED | o185i195 |
+----------------------------------+----------+
Cloning process finished on 2006-08-08 at [17:10:51]
Database report:
| cloned | error | unknown
ne1 | 1 | 0 | 0
sfs | 0 | 0 | 0
ne2 | 0 | 0 | 0
ne3 | 0 | 0 | 0
ne4 | 0 | 0 | 0
test | 0 | 0 | 0
6.17 HP Insight CMU CLI 107
Zobrazit stránku 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 190 191