set fc-connection
The -set fc-connection command modifies an existing FC connection to a server profile.
Syntax
-set fc-connection profilename <profileName>
-portnumber <Port>
[-fabric <FabricName>]
[-speed <Auto|1Gb|2Gb|4Gb|8Gb|Disabled>]
[bootpriority <priority>]
[bootport <portName>]
[bootlun <LUN>]
Parameters
Table 12 Parameter descriptions for -set fc-connection
OptionalRequiredDescriptionParameter
xThe name of the server
profile that contains the
connection to modify
-profilename
xThe port number of the
connection being modified.
-portnumber
xThe name of an existing
fabric to associate with the
-fabric
connection. If the fabric
name is not specified, then
the connection will be
marked as Unassigned
but associated with a
specific bay.
xThe port speed of the
connection port. Valid values
-speed
include auto, 1Gb, 2Gb,
4Gb, 8Gb and disabled.
The default port speed is
auto.
NOTE: For HP 4Gb VC-FC
Modules or HP Virtual
Connect 4Gb FC Modules,
supported speed values
include: auto, 1Gb, 2Gb,
4Gb, and disabled. If it is
set to 8Gb, the speed is
auto-negotiated by VC.
xControls whether the FC
HBA port is enabled for
-bootpriority
SAN boot and affects the
BIOS boot order. Valid
values include the following:
Usebios
primary
secondary
disabled
Only one boot parameter is
allowed per FC connection.
34 Using VCEM commands