Hp OneView for VMware vCenter Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Software Hp OneView for VMware vCenter. HP OneView for VMware vCenter User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 92
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP Insight Control for VMware vCenter
Server
User Guide
Abstract
This document contains detailed instructions for configuring and using HP Insight Control for VMware vCenter Server. The
intended audience is system administrators who are experienced in virtual and physical IT infrastructure administration and
understand server virtualization, storage, and networking concepts.
HP Part Number: 661306-001
Published: December 2011
Edition: 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 91 92

Shrnutí obsahu

Strany 1 - User Guide

HP Insight Control for VMware vCenterServerUser GuideAbstractThis document contains detailed instructions for configuring and using HP Insight Control

Strany 2

servers. After you configure storage arrays and management servers, configure the VMware VASAprovider (optional).For information about initialization

Strany 3 - Contents

Figure 2 Setting storage pool accessTo access the Storage Administrator Portal:1. Log in to the vSphere Client.2. Select a host, VM, or datastore, and

Strany 4 - 4 Contents

2. Use the following procedures to add, modify, and remove arrays and management servers:• “Adding HP P6000 Command View management servers” (page 12)

Strany 5 - Contents 5

TIP: Click Add All or Remove All, respectively, to add or remove all arrays.The Add HP P6000 Command View (4 of 4) page appears, listing the storage p

Strany 6 - 1 Overview

6. Click Next.The Add P6000 EVA (3 of 3) page appears, listing the storage pools on the selected P6000EVA array.7. Select the Full Access check box fo

Strany 7

IMPORTANT: You must install version 1.1.2.0 of the MSA SMI-S proxy provider to addsupport for the MSA in your VMware environment. Earlier versions of

Strany 8 - Manual association

8. Click Finish.The P2000 G3 MSA System is added to the Configured Arrays and Management Serverslist.Adding HP P9000 arraysTo add an HP P9000 array:1.

Strany 9

5. Click the Storage Properties tab.The list of configured arrays and management servers appears, displaying the followinginformation:• Name: Array or

Strany 10

2. Select an array or management server in the Configured Arrays and Management Serverslist, and then click Modify.The Modify management server or arr

Strany 11

2. Select an array or management server in the Configured Arrays and Management Serverslist, and then click Remove.The Remove array or management serv

Strany 12

© Copyright 2011 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Strany 13 - Adding HP P6000 EVA arrays

4. Select Generate a Certificate Signing Request.5. Enter the following information:• Country• State• Locality• Organization• Common Name – The fully

Strany 14 - Adding HP MSA2000 G2 arrays

3 Using Insight Control for vCenterThis chapter describes the processes for accessing and using the software.Accessing Insight Control for vCenterAfte

Strany 15

For the Server Module for vCenter, the Overview page includes health status information and linksto iLO, Onboard Administrator, HP SIM, and Virtual Co

Strany 16 - Adding HP XP arrays

This section describes how to access the following information:• Cluster managementHealth summary◦◦ Infrastructure◦ Power◦ Firmware• Host/Server manag

Strany 17

The Cost Advantage value is calculated as follows:Cost Advantage = (number of hours the server was down) × (power cost) × (average power)Entering the

Strany 18

Viewing infrastructure information for a clusterTo view information about a selected cluster:1. Select a cluster in the inventory tree.2. Click the HP

Strany 19

To update firmware for the cluster or selected systems in the cluster, complete the following steps:1. Select the Smart Component Update tabbed page.2

Strany 20

Summary tabThe Summary tab displays a health summary for the selected HP ProLiant and BladeSystem server.Use this tab to view the server, power, healt

Strany 21 - HP Management pane overview

3. Click Power/Thermal in the Server Management section of the HP Management pane.The Power/Thermal page displays the following information:Server tab

Strany 22

Figure 10 Virtual Connect Network DiagramViewing and updating firmware on selected serversNOTE: Firmware information is available for ESXi systems onl

Strany 23

Contents1 Overview...62 Configuring Insight Control for

Strany 24 - Managing clusters

2. Select one of the following options and enter the required information:• Update from URL — Enter the URL of a web server from which to distribute t

Strany 25

PrerequisitesBefore using the wizard, you must have installed:• HP Insight Control for vCenter• HP RDP from the HP Insight Rapid Deployment website.•

Strany 26 - Managing servers

Figure 11 HP Insight Software tabWhen using the HP Insight Software tab:• Click Properties to view and configure management servers and arrays. For mo

Strany 27

◦ “Viewing related host information” (page 41)◦ “Viewing detailed storage information” (page 41)• Click Help for context-sensitive help.Refreshing Sto

Strany 28

To start a data refresh immediately:1. Click the Refresh link in the top right corner of any Storage Module for vCenter page.The HP Insight Software t

Strany 29

2. Change the following parameters:• Caching.RefreshInterval: Specifies the time, in milliseconds, to wait betweencache refreshes• Caching.InactivityT

Strany 30 - Launching into HP tools

• Click the triangle icon to the left of a column heading to sort data by the selected column.To sort data in multiple columns, Shift+Click the title

Strany 31 - Prerequisites

NOTE: The HP Storage Used value might differ from the HP Storage Provisioned value ifthin provisioning or demand-allocated snapshots are used.• HP Sto

Strany 32

NOTE: The HP Storage Used value might differ from the HP Storage Provisioned value ifthin provisioning or demand-allocated snapshots are used.• HP Sto

Strany 33 - Manually refreshing the data

Storage ArraysThe Storage Arrays section lists the configured arrays that provide storage to the selected datastore.TIP: To start the array management

Strany 34 - Restarting a data refresh

Customizing Storage Module for vCenter tables...35Viewing VM or datastore overview i

Strany 35

Viewing summary informationThe Related Virtual Machines page displays the following information for the VMs associated withthe selected host, cluster,

Strany 36 - Viewing summary information

• “Viewing paths” (page 44)• “Viewing replications” (page 47)Viewing related host informationTo view information about a selected host, hosts where th

Strany 37 - Viewing detailed information

NOTE: The detailed information provided in the Storage Module for vCenter tabs might varydepending whether a VM, host, or datastore is selected. For e

Strany 38

• Array Disk Type: Array disk type and characteristics (for example, HP_LHN_VOLUME,HP_EVA_SNAPSHOT, or HP_XP_THIN_PROVISIONED_VOLUME)• Storage PoolP90

Strany 39

• Virtual Disk Allocated Capacity: Disk capacity reserved by VMware for the VMDK or RDMFor an RDM, this value will match the provisioned capacity valu

Strany 40

Figure 22 Paths tabThis tab displays the following information:• Array Disk NameP9000/XP: Emulation type and LDKC:CU:LDEV (for example, HP OPEN-V-CVS

Strany 41

• Array Port: Storage array's port identifier used for this pathP9000/XP: Port number◦◦ P6000 EVA: Port name configured in P6000 Command View◦ P4

Strany 42 - Viewing storage disks

• Active Path: Specifies whether the path is active or in standby statusIf a path is active and then goes offline, a standby path takes over.• Path ID

Strany 43 - Viewing virtual disks

Figure 24 View All tabThe same VM will appear multiple times in this table, based on the number of available paths toa storage disk. To hide duplicate

Strany 44 - Viewing paths

◦ P4000: IQN assigned to the host◦ P2000/MSA2000 (FC, SAS): WWN for the host port on the host end of this path◦ P2000/MSA2000 (iSCSI): IQN assigned to

Strany 45

Clicking HP Insight power management launch link does not go to expected HP SIM page...78Cost Advantage field not showing values...

Strany 46

◦ P4000: Not applicable◦ P2000/MSA2000: Not applicable• Active Path: Specifies whether the path is active or in standby status• Path ID: Path ID assig

Strany 47 - Viewing replications

4 Provisioning storageThe Storage Module for vCenter supports storage provisioning for P6000 EVA, P2000 G3 MSA,and P4000 arrays. You can perform stora

Strany 48

Changing the default location for all P6000 EVA arraysTo change the default location for all P6000 EVA arrays, modify the value \Virtual Disks\in the

Strany 49

2. Use one of the following methods to start the Add Datastore wizard:• Right-click a host or cluster and select HP Insight Software→Add Datastores.•

Strany 50 - ◦ P4000: Not applicable

Figure 26 Storage Array capacityIf there is not enough space available in the selected storage pool, a message is displayedin the Warnings box.• RAID

Strany 51 - 4 Provisioning storage

6. Click Next.The Add Datastores – Review and Validate window opens. See Figure 28 (page 55).Figure 28 Add Datastores – Review and Validate window (be

Strany 52 - Adding a new datastore

Figure 30 Add Datastores – Summary window9. Click Finish to create the specified datastores.You can view the progress of the task in the Recent Tasks

Strany 53 - Adding a new datastore 53

Figure 31 Expand Datastore window3. Enter the requested new capacity in the Requested Datastore Capacity box.The following rules apply when expanding

Strany 54 - 54 Provisioning storage

To delete a datastore:1. Start the vSphere Client.2. Use one of the following methods to specify a datastore to delete:• Right-click a datastore and s

Strany 55 - Adding a new datastore 55

Creating a VM from a templateYou can create one or more VMs from a VM template. While creating VMs:• The VM template must exist in the vSphere Client.

Strany 56 - Expanding a datastore

1 OverviewHP Insight Control for VMware vCenter Server (Insight Control for vCenter) includes the core InsightControl capabilities for VMware vCenter

Strany 57 - Deleting a datastore

3. Enter the following information:• Owner: Select the host or cluster that will own the new VMs. This information is enteredautomatically if you init

Strany 58 - Deleting an unassigned volume

Figure 35 Create Virtual Machines – Specify Names window7. Enter the following information:• VM Names: Enter the base name for the new VMs. The # symb

Strany 59 - Creating a VM from a template

Figure 36 Create Virtual Machines – Review and Validate window (before validation)9. Click Next to validate that it is possible to create the VMs.The

Strany 60 - 60 Provisioning storage

Figure 38 Create Virtual Machines – Summary window11. Click Finish to create the specified VMs and datastores.You can view the progress of the task in

Strany 61

2. Use one of the following methods to start the Clone Virtual Machine wizard:• Right-click a VM and select HP Insight Software→Clone Virtual Machine.

Strany 62 - 62 Provisioning storage

Figure 40 Clone Virtual Machine – Specify New Names window5. Enter the following information:• New VM Names: Enter the base name for the new VMs. The

Strany 63 - Cloning a VM

Figure 41 Clone Virtual Machine – Review and Validate window (before validation)7. Click Next to validate that it is possible to create the cloned VMs

Strany 64 - 64 Provisioning storage

Figure 43 Clone Virtual Machine – Summary window9. Click Finish to create the specified VMs.You can view the progress of the task in the Recent Tasks

Strany 65 - Cloning a VM 65

5 Viewing hardware alert notificationsThis chapter describes the Insight Control for vCenter hardware alert events and alarms.Insight Control for vCen

Strany 66 - 66 Provisioning storage

Enclosure name: Interconnect in bay number status changed to other.Enclosure name: Interconnect in bay number: insertedEnclosure name: Interconnect in

Strany 67 - Cloning a VM 67

2 Configuring Insight Control for vCenterAfter installation, configure the server and storage modules.IMPORTANT: Proxy-enabled Windows clients can fai

Strany 68 - Onboard Administrator events

Enclosure name: Power subsystem status changed to degraded.Fan zone eventsEnclosure name: Fan zone number status changed to unknown.Enclosure name: Fa

Strany 69

HP SNMP agent and HP CIM provider eventsHP Insight Control for vCenter registers with HP SNMP agents and HP CIM providers to receivetraps from HP SNMP

Strany 70

Alarm iconWhen an alarm occurs, an icon appears to the right of the vSphere Client window along the barabove the vSphere Client tabs or on the host ic

Strany 71

6 TroubleshootingBefore troubleshooting issues with Insight Control for vCenter, you must:• Verify that the correct user name and password are entered

Strany 72 - Alarm icon

Action:• Ensure that a host, cluster, datastore, or VM is selected in the left pane of the vSphere Clientwindow.• Use the arrows to scroll through the

Strany 73 - 6 Troubleshooting

Figure 44 Internet Explorer script error: buttons.0.0 is nullPossible cause: The vSphere user is not assigned the vCenter Administrator role.Action: C

Strany 74 - 74 Troubleshooting

Action: Close the window, add the vCenter host to the Internet Explorer list of trusted sites, andthen start the vSphere Client again. For instruction

Strany 75 - Management pane

Software section, and then click Properties in the upper right corner. Enter the iLO settings,and then click OK.• Configure iLO from the HP Insight So

Strany 76 - 76 Troubleshooting

settings for each iLO, Onboard Administrator, or and HP SIM on the network. For moreinformation about managing passwords and other system administrati

Strany 77

c-Class server blade and that the corresponding Onboard Administrator is accessible fromthe default system browser on the system where Insight Control

Strany 78 - 78 Troubleshooting

Onboard Administrator Single Sign-OnTo enable SSO, you must upload the Insight Control for vCenter certificate to the OnboardAdministrator.1. On the O

Strany 79

(page 73). For troubleshooting information specific to the Server Module for vCenter, see“Troubleshooting the Server Module for vCenter” (page 76).Sto

Strany 80 - 80 Troubleshooting

Port conflict occurs when trying to configure P6000 Command View and MSA proxyprovider for use with Storage Module for vCenterPossible cause: P6000 Co

Strany 81

RMI connection exception in Storage Overview pageWhen a Storage Module for vCenter data refresh is in progress, and a user initiates the VMwarere-scan

Strany 82 - Connection refused:connect

1. Select a host in the vSphere Client.2. Click the Configuration tab.3. Click Advanced Settings in the Software pane.4. Click Scsi in the list of adv

Strany 83

not met, JBoss logs erroneous exceptions indicating that several ports are in use, but the reportedports are not listed in the output of the netstat –

Strany 84 - 84 Troubleshooting

7 Support and other resourcesThis chapter describes the support available for Insight Control for vCenter.Information to collect before contacting HPB

Strany 85 - 7 Support and other resources

HP authorized resellersFor the name of the nearest HP authorized reseller, see the following sources:• In the United States, see the HP U.S. service l

Strany 86 - Related information

A Firewall port requirementsTo achieve full functionality, an Insight Control for vCenter 6.3.1 server requires that the firewallports listed in Table

Strany 87 - A Firewall port requirements

GlossaryCIM Common Information Model.CLI Command-line interface. An interface comprised of various commands which are used to controloperating system

Strany 88 - Glossary

SPOCK Single Point of Connectivity Knowledge website. SPOCK is the primary portal used to obtaindetailed information about supported HP storage produc

Strany 89

4. Enter the iLO Username, iLO Password, iLO IP address and iLO MAC address, and then clickOK.Using the Insight Control for vCenter Properties page1.

Strany 90 - 90 Index

IndexAaccessing HP Insight Control for vCenter, 21adding arraysMSA2000 G2, 14P2000 G3 MSA System, 15P4000, 14P6000 EVA, 13P9000, 16XP, 16adding manage

Strany 91

troubleshooting, 73HP Insight Software tab not available, 73HP Management paneusing, 21HP SIM events, 71IiLO logs, 30IML, 30infrastructure, 25initiali

Strany 92 - 92 Index

single sign-on see SSOsmart components, 25, 29SSOenabling, 8failure, 77Storage Administrator Portalabout, 10troubleshooting, 80storage disksviewing, 4

Komentáře k této Příručce