9-14
Time Protocols
SNTP: Viewing, Selecting, and Configuring
Changing the SNTP Poll Interval.
For example, to change the poll interval to 300 seconds:
ProCurve(config)# sntp poll-interval 300
Changing the Priority. You can choose the order in which configured
servers are polled for getting the time by setting the server priority.
For example, to set one server to priority 1 and another to priority 2:
ProCurve(config)# sntp server priority 1 10.28.22.141
ProCurve(config)# sntp server priority 2
2001:db8::215:60ff:fe79:8980
Disabling Time Synchronization Without Changing the SNTP
Configuration. The recommended method for disabling time synchroniza-
tion is to use the timesync command.
For example, suppose SNTP is running as the switch’s time synchronization
protocol, with Broadcast as the SNTP mode and the factory-default polling
interval. You would halt time synchronization with this command:
ProCurve(config)# no timesync
If you then viewed the SNTP configuration, you would see the following:
Syntax:
sntp poll-interval < 30..720 >
Specifies how long the switch waits between time polling
intervals. The default is 720 seconds and the range is 30 to
720 seconds. (This parameter is separate from the poll inter-
val parameter used for Timep operation.)
Syntax: sntp server priority <1 - 3> <ip-address>
Specifies the order in which the configured servers are polled
for getting the time. Value is between 1 and 3.
Note: Both IPv4 and IPv6 addresses can be entered. For more
information about IPv6 addresses, see the “IPv6 Configura-
tion Guide” for your switch.
Syntax: no timesync
Halts time synchronization without changing your SNTP
configuration.