Hp XP Array Manager Software Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Úložný prostor Hp XP Array Manager Software. HP XP Array Manager Software User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 105
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP StorageWorks
XP24000 LUN Manager User's Guide
Part number: T5214-96006
F
irst edition: June 2007
Zobrazit stránku 0
1 2 3 4 5 6 ... 104 105

Shrnutí obsahu

Strany 1 - HP StorageWorks

HP StorageWorks XP24000 LUN Manager User's Guide Part number: T5214-96006 First edition: June 2007

Strany 2 - Description

• HP StorageWorks XP24000 Disk/Cache Partition User’s Guide • HP StorageWorks XP24000 Volume Retention Manager User’s Guide • HP StorageWorks XP240

Strany 3 - Contents

100 Performing LUN Manager Operations Using Configuration File Loader

Strany 4

7 Troubleshooting Troubleshooting For troubleshooting information on the storage system, see the HP StorageWorks XP24000 Disk Array Owner's Guide

Strany 5

102 Troubleshooting

Strany 6 - Figures

AGlossary, Acronyms, and Abbreviations Table 19 Glossary, Acronyms, and Abbreviations CU control unit cv, cvs custom-sized volume, also called customi

Strany 7

104 Glossary, Acronyms, and Abbreviations

Strany 8

Index A AIX finding WWN,37 appendix,103 audience, 9 C conventions document,10 storage capacity values,10 D document conventions,10 related documentatio

Strany 9

http://www.hp.com/support Before contacting HP, collect the following information: • Product model names and numbers • Technical support registratio

Strany 10

12 About this Guide

Strany 11 - Documentation Feedback

1 Overview of HP StorageWorks XP LUN Manager Operations Overview of LUN Manager LUN Manager enables the open-systems user to define the paths for logic

Strany 12 - About this Guide

Overview of HP StorageWorks XP LUN Manager Operations 14

Strany 13 - XP LUN Manager Operations

2 About LUN Manager Operations The HP storage system can be connected to open-system server hosts of different platforms (for example, UNIX servers an

Strany 14

000B000CAfter server hosts are classified into host groups, you must associate host groups to logical volumes. In Figure 1 on page 16, the host group h

Strany 15 - Caution:

If a hardware failure (such as a CHA failure) occurs, there is a chance that some LU paths will be disabled and some I/O operations stopped. To avoid

Strany 16 - About LUN Manager Operations

Figure 3 Disabling LUN Security Host group 0 is the only host group reserved for each port by default. If you use the LUN Manager window to view a li

Strany 17 - Configuring LUN Security

3 Preparing for LUN Manager Operations System Requirements To use LUN Manager, you need: • the storage system • a computer that runs Remote Web

Strany 18

Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required

Strany 19 - Operations

20 Preparing for LUN Manager Operations

Strany 20

4 Using the LUN Manager GUI Fibre Channel Windows LUN Manager Window When you launchLUN Manager, the LUN Manager window appears. The LUN Manager windo

Strany 21 - 4 Using the LUN Manager GUI

The Fibre folder:If you double-click the Fibre folder, Fibre Channel ports in the storage system appear as icons. On the right side of each icon is th

Strany 22 - LU Path List

Figure 6 The LU Path List Displays LUNs assigned to logical volumes. LUNs (logical unit numbers) are address numbers assigned to logical units (LUs),

Strany 23 - Figure 6 The LU Path List

• The Add WWN button registers host bus adapters in a host group. Before using this button, you must select a host group in the LU Path tree and als

Strany 24 - LDEV List

Figure 8 The LDEV List LDKC Displays the LDKC number 00. This number is grayed out. CU Lists CU images. LDKC:CU:LDEV Indicates logical volumes. This

Strany 25 - DEV List

Port Window When you launch LUN Manager and click the Port tab, the Port window appears. This window lets you make settings for Fibre Channel ports.

Strany 26 - Port Window

Port List The Port list displays all ports on a channel adapter if you select a channel adapter in the Package tree. The Port list displays all ports

Strany 27 - Change Port Mode Box

Figure11TheChangePortModeBoxDisplayingInformationaboutFibreChannelPorts Select a Port To change settings for a port, select the port from this drop-do

Strany 28

Figure 12 The Authentication Window (When Selecting Fibre Folder) Port Tree Use this tree to find information about user authentication on each port.

Strany 29 - Port Tree

Contents AboutthisGuide ... 9 IntendedAudience... 9 RelatedDocumentation...

Strany 30 - FC Switch I

Port Information List Port Name Displays Fibre Channel port names. For details, see Table 7 on page 69 through Table 8 on page 73. Time out Displays

Strany 31

Figure 14 The Authentication Window (When Selecting Port Icon under Fibre Folder) Port Tree Use this tree to find information about user authenticatio

Strany 32 - Authentica

CLX-Y Indicates a Fibre Channel port. host group name Indicates that the host group performs authentication of hosts. Indicates that the host group do

Strany 33 - 5PerformingLUN Manager

5PerformingLUN Manager Operations Launching LUN Manager for Fibre Channel Operations To start LUN Manager, take the following steps: 1. Start the Web

Strany 34

Finding WWN for Windows NT or Windows 2000 HP currently supports the Emulex Fibre Channel adapter in a Windows NT or Windows 2000 environment, and wil

Strany 35 - Finding WWN for HP-UX

Figure 16 LightPulse Utility/NT Window Finding WWN for HP-UX To find the WWN in an HP-UX environment (see Figure 17 on page 36): 1. Verify that the fib

Strany 36 - Finding WWN for Solaris

Figure 17 HP-UX Worldwide Name Finding WWN for Solaris HP currently supports the JNI Fibre Channel adapter in a Sun Solaris environment. This document

Strany 37 - Creating Ho

Figure 18 Sun Solaris Worldwide Name Finding WWN for AIX, IRIX, or Sequent To find the WWN in an AIX, SGI Irix, or Sequent environment, use the fibre sw

Strany 38

The setting is applied to the storage system. Note: After you click the Option button, the dialog box expands to display the list of host mode options

Strany 39

If thehostmode ofahost groupis 0C Windows and an LU path is defined between the host group and a logical volume, you cannot combine the logical volume

Strany 40

DefiningFibreChannelLUPaths... 33 FindingWWNs... 33 FindingWWNforWindowsNTorWindows2000 ..

Strany 41

Notes: • A nickname can consist of up to 32 ASCII characters (letters, numerals, and symbols). However, you cannot use the following characters for n

Strany 42

Figure 20 The Add New WWN Dialog Box (When Registering a Host that Has Previously been Connected to the Storage System) Figure 21 The Add New WWN Dial

Strany 43 - Overview

2. In the tree, select a host group. 3. From the CU drop-down list above the LDEV list, select a CU number. The LDEV list displays LDEVs in the spec

Strany 44

• Deleting user information for hosts (see “Deleting Host User Information”onpage52) • Specifying user information for host groups (when performing m

Strany 45

•On the storage system: Use LUN Manager to specify whether to perform authentication of hosts on each host group. On a host group that performs authe

Strany 46

Figure 23 Flow of Authentication of Hosts (In a Fibre Channel environment) Each case in the flow is explained as follows. Case A to Case D in Figure 23

Strany 47 - Switch Authentication

Thehostwillconnect to thestorage system withoutauthenticationofthe host, regardlessof whetherornot thehostisconfigured for authentication by host group

Strany 48

The user information for Host B is also registered on host group 1, but the authentication setting is disabled. Therefore, Host B can connect to the s

Strany 49

Figure 25 Flow of Authentication of Fibre Channel Switch Each case in the flow is explained as follows. Case A to Case D in Figure 25 on page 48 corres

Strany 50

Regardless of the setting on the Fibre Channel switch, the port performs authentication of the Fibre Channel switch, but results in failure. The Fibr

Strany 51

FunctionTags... 87 Configuration Definitions ... 88 Comments ...

Strany 52

3. In the Port tree, double-click the Subsystem folder. If the storage system contains any Fibre Channel adapters, the Fibre folder appears below th

Strany 53

The specified user information for the host is added in blue in the Authentication Information (Host) list of the Authentication window. 7. Click the

Strany 54 - Port Authentication

Figure 27 The Change User Information (Host) Dialog Box Deleting Host User Information To delete user information for a host from a host group: 1. Ma

Strany 55

Figure 28 The Delete Authentication Information Dialog Box Registering Host Group User Information To perform mutual authentication, you need to speci

Strany 56

Figure 29 The Specify Authentication Information Dialog Box Clearing Host Groups User Information To clear user information for a host group: 1. Make

Strany 57

Specify the period of time from when authentication fails to when the next authentication session ends. Valid periods are between 15 and 60 seconds. T

Strany 58 - Switch Authentication Mode

The setting is applied to the storage system. Figure 31 The Default Setting(User Name/Secret) Dialog Box Switch Authentication Setting Switch User Inf

Strany 59

Figure 32 The Specify Authentication Information Dialog Box Clearing Switch User Information To clear the user information for a Fibre Channel switch:

Strany 60 - Deleting

Figure 33 The Clear Authentication Information Dialog Box Setting the Switch Authentication Mode To specify the authentication mode of a Fibre Channel

Strany 61 - Warning:

7. Click the OK button to close the message. The setting is applied to the storage system. To return the Fibre Channel switch setting so that the swi

Strany 62 - Deleting Host Groups

...Figures 1 LU Paths ConfigurationinaFibreChannelEnvironment ... 16

Strany 63

Figure 34 TheChangeWWN &NameDialogBox Figure 35 The Dialog Box that Displays the Host Bus Adapters to be Changed Deleting Host Bus Adapters from H

Strany 64

2. In the WWN list, locate WWNsthatare notregisteredinany host group. If the hostgroup column is blank, the WWN is not registered in any host group.

Strany 65 - Setting the Fi

Note: After you click the Option button, the dialog box expands to display the list of host mode options. The No. column indicates option numbers. Sel

Strany 66 - Initiator/External Mix Mode

LU paths areremoved from thetable on theright of thetree. TheLUNscorresponding to the removed LU paths are displayed in blue. 5. Click Apply in the L

Strany 67

Table 6 Available Addresses for Fibre Channel Ports Port Address (AL-PA) Loop ID Port Address (AL-PA) Loop ID Port Address (AL-PA) Loop ID Port Addres

Strany 68

• If you select a channel adapter, the Port list displays a list of Fibre Channel ports on the channel adapter. 3. Select a port from the Port list

Strany 69

•If you select the Fibre folder, the Port list displays a list of Fibre Channel ports in the storage system. • If you select a channel adapter, the P

Strany 70

Figure38PortsinHighSpeedModeorInitiator/ExternalMIXmode If High Speed mode is applied to the four ports in a port block, only two of the ports can be

Strany 71

Port names can differ, depending on whether ports are in Standard mode, High Speed mode, or Initiator/External MIX mode. For detailed information abou

Strany 72

Table 7 Port Serial Numbers and Port Names (4-port Fibre Channel Adapter) Port serial number Standard mode High Speed mode or Initiator/External MIX

Strany 73

...37 FC-ALTopologyandPoint-to-pointTopology ... 65 38 PortsinHighSpeedModeorInitiator/ExternalMIXmode...

Strany 74

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 75

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 76

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 77 - Viewing a L

Table 8 Port Serial Numbers and Port Names (8-port Fibre Channel Adapter) Port serial number Standard mode High Speed mode or Initiator/External MIX

Strany 78 - Deleting LU Paths

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 79

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 80 - Using LUN Security

Port serial number Standard mode High Speed mode or Initiator/External MIX mode Port serial number Standard mode High Speed mode or Initiator/Exte

Strany 81 - Disabling LUN Security

The tree displays a list of CHA (channel adapter of Fibre Channel) packages (Figure 9 on page 26). 3. Double-click a channel adapter icon ( , or )

Strany 82 - Deleting Command Devices

Figure 39 The Concatenation List Dialog Box Deleting LU Paths Caution: Do not remove LU paths when host I/O is in progress. To delete LU paths: 1. St

Strany 83 - Related topic

Figure 40 Information about LU Paths to be Deleted Note: If you delete numerous paths at one time, the deletion may take time and the dialog box may s

Strany 84

1..2..3..4..5..6..7..8..9..10..11..12..13..14..15..16..17..18..19..Tables DocumentConventions... 10 HostModesforHostGroups

Strany 85 - File Loader

d. Double-click the copy destination port to display host groups below the port. e. Right-click the host group to which you want to paste paths. Nex

Strany 86

By default, LUN security is disabled on each port. When configuring your system, you must enable LUN security on ports. Note: If a port has the Extern

Strany 87 - Spreadsheet Com

commands can be used to create and split pairs. To enable the system administrator to enter RAID Manager commands from open-system hosts, you must sp

Strany 88 - Configuration Definitions

2. In the upper-right LU Path list or in the lower-right LDEV list, select and right-click the desired command device. Notes: in the tree. • If noth

Strany 89 - Comments

84 Performing LUN Manager Operations

Strany 90 - LUN Manager Spre

6PerformingLUN Manager Operations Using Configuration File Loader You can use Configuration File Loader to define Channel Adapter (CHA) settings, Port

Strany 91 - Setting the CHA Mode

Spreadsheet File Requirements You will need to write the spreadsheet according to specificrules andinaspecificformat. Figure 43 on page 86 shows an exam

Strany 92 - Port Setti

Spreadsheet Components The spreadsheet consists of the following components: • Spreadsheet Declaration (see “Spreadsheet Declaration”onpage87) • Funct

Strany 93 - Setting the H

• The row after the function tag indicates the required setting items (Cha and PcbMode in the example) for the function. The setting items are separa

Strany 94

• Do not write the identical index more than once in the same function tag. • To change some,but notall,ofthe settings on thesameconfiguration definit

Strany 95 - Setting the WWN Information

About this Guide This user's guide describes and provides instructions for using the LUN Manager software to configure and perform LUN Manager ope

Strany 96 - Setting the LU Path

LUN Manager Spreadsheet Settings The following LUN Manager functions can be defined by using Configuration File Loader: • Channel Adapter (CHA) setting

Strany 97

Table 11 LUN Manager Spreadsheet Format Function Tag Column [Cha] [Port] [HostGroup] [WWN] [LUN] [LDEV] 1st Cha Port Port Port Port Ldkc 2nd P

Strany 98 - Error Check

Table 12 Available Configuration Values for the [CHA] Tag Column Item Available Values 1st, 11th (Index) Cha One of the following can be set: CHA-1AL,

Strany 99 - Third Error Check

Table 13 Available [Port] Tag Configuration Values Column Item Available Value 1st, 11th (Index) Port Set one of the following (Maximum number of port

Strany 100

Table 14 Available Configuration Values for the [HostGroup] Tag Column Item Available Values 1st, 11th (Index) Port One of the following can be set (Ma

Strany 101 - 7 Troubleshooting

0 1 2 3 4 5 6 7 .. .. 28 29 30 31 0 1 0 1 1 1 0 0 .. .. 1 1 1 1 Option Flag ID 5 C Option Flag F Figure 46 ConceptofHostModeOption ID 0~3 4~

Strany 102 - Troubleshooting

Table 16 Available Configuration Values for the [WWN] Tag Column Item Available Values 1st, 11th (Index) Port One of the following can be set (Maximum

Strany 103 - Abbreviations

Table 17 Available Configuration Values for the [LUN] Tag Column Item Available Values 1st, 11th (Index) Port One of the following can be set (Maximum

Strany 104

Table 18 Available Configuration Values for the [LDEV] Tag Column Item Available Value 1st, 11th (Index) Ldkc 00 2nd, 12th (Index) Cu 00 - FE. Set wit

Strany 105

LDEV:00 - FF LUN: 0000 - 07FF Group ID: 00 - FE Host Mode: 00 - 4F • Level 2 check: The current settings are compared to the imported settings and