Hp ProLiant DL580 G3 Server Uživatelský manuál Strana 25

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 190
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 24
Server component identification 25
LED Description
SCSI BP The SCSI backplane is missing or not properly installed.
MEM A memory board is not properly installed.
MEM BP A memory backplane is missing or not properly installed.
FSB One or more of the following conditions exist:
A processor or PPM is missing or not properly installed.
An FSB configuration error was detected.
PROC A processor is missing or not properly installed.
OVER TEMP The internal temperature has exceeded operating levels.
NO BOOT A "no boot" condition was detected.
P84 Switch set to display port 84 codes.
P85 Switch set to display port 85 codes.
DIMM slot locations
Item Description Bank
1 DIMM slot 1 A
2 DIMM slot 2 A
Zobrazit stránku 24