HP ProLiant BL25p Server Blade Maintenance and Service Guide December 2005 (Fourth Edition) Part Number 377851-004A
Removal and replacement procedures 10 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
Removal and replacement procedures 11 Server blade preparation To service any internal server blade component, power down the server blade and remov
Removal and replacement procedures 12 Access panel To remove the component: 1. Power down the server blade and remove it from the server blade encl
Removal and replacement procedures 13 2. Install the hard drive. 3. Determine the status of the hard drive from the hot-plug hard drive LEDs (&quo
Removal and replacement procedures 14 • Both DIMM slots in a memory bank must be populated. • Both DIMMs in a memory bank must be identical. • Pro
Removal and replacement procedures 15 3. Open the processor cage latch. 4. Open the processor cage. 5. Remove the heatsink. 6. Open the processor
Removal and replacement procedures 16 3. Remove the protective cover from the thermal interface. CAUTION: After the cover is removed, do not tou
Removal and replacement procedures 17 CAUTION: To avoid overheating of the dual core processor, the old air baffle must be replaced when upgradin
Removal and replacement procedures 18 HP Smart Array 6i battery-backed write cache enabler (optional) To remove the component: 1. Power down the se
Removal and replacement procedures 19 3. Remove the air baffle. To replace the component, reverse the removal procedure. CAUTION: To avoid overh
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties
Removal and replacement procedures 20 5. Press the fan retention tab and lift the assembly away from the system board. To replace the component, re
Removal and replacement procedures 21 IMPORTANT: Refer to the label on the FC mezzanine to verify compatibility with the server blade. Standard
Removal and replacement procedures 22 SCSI backplane To remove the component: 1. Power down the server blade and remove it from the server blade en
Removal and replacement procedures 23 Power converter module To remove the component: 1. Power down the server blade and remove it from the server
Removal and replacement procedures 24 4. Release the latches and lift the DC filter module away from the system board while pushing the power connec
Removal and replacement procedures 25 8. Slide the power button/LED board out of the front of the chassis. IMPORTANT: Be sure the tab at the end
Removal and replacement procedures 26 4. Remove the existing battery by pushing the tab aside and pulling the battery straight up. To install the s
Removal and replacement procedures 27 13. Disconnect the LED cable from the system board before removing the system board from the server blade. 14.
Removal and replacement procedures 28 Server blade bay blank Remove the server blade blank from the server blade enclosure. CAUTION: To prevent
Diagnostic tools 29 Diagnostic tools In this section HP Insight Diagnostics...
Contents 3 Contents Illustrated parts catalog ...
Diagnostic tools 30 • For Linux: IML Viewer Application • From within the iLO user interface • From within HP Insight Diagnostics (on page 29) For
Server component identification 31 Server component identification In this section Front panel components ...
Server component identification 32 Front panel LEDs Item Description Status 1 UID LED Blue = Identified Blue flashing = Active remote manageme
Server component identification 33 Item Description Status 10 Fault status Flashing = Fault process activity Off = No fault process activity * Ac
Server component identification 34 Internal components Item Description 1 System maintenance switch (SW1) 2 DC filter module 3 Standard NIC m
Server component identification 35 Item Description 18 HP Smart Array 6i Controller 19 Power converter modules 20 FC mezzanine (optional) System
Server component identification 36 IMPORTANT: When the server blade boots after NVRAM is cleared, a delay of up to 2 minutes is normal. During thi
Server component identification 37 Item Connector Description 6 iLO RJ-45 (10/100 Ethernet) For connecting an Ethernet to the server blade iLO inter
Server component identification 38 Activity LED (1) Online LED (2) Fault LED (3) Interpretation On or flashing Flashing Off Do not remove the drive.
Specifications 39 Specifications In this section Environmental specifications...
Contents 4 Index...
Acronyms and abbreviations 40 Acronyms and abbreviations BBWC battery-backed write cache BIOS Basic Input/Output System DDR double data rate ESD
Acronyms and abbreviations 41 PSP ProLiant Support Pack RBSU ROM-Based Setup Utility RILOE Remote Insight Lights-Out Edition ROM read-only memory
Index 42 A access panel 12 air baffle 18, 19, 22 array controllers 34 B batteries, care and storage 25 battery-backed write cache 34 batter
Index 43 P power button 31, 34 power button/LED board 24 power converter module 23, 34 PPM failure LEDs 37 preparation procedures 11 proces
Illustrated parts catalog 5 Illustrated parts catalog In this section Customer self repair ...
Illustrated parts catalog 6 Server blade components Item Description Spare part number Customer replaceable? Mechanical components 1 Access pan
Illustrated parts catalog 7 Item Description Spare part number Customer replaceable? b) 2.6-GHz, single-core AMD Opteron™ Model 252 * 381837-001
Removal and replacement procedures 8 Removal and replacement procedures In this section Safety considerations....
Removal and replacement procedures 9 Server blade warnings and cautions WARNING: To reduce the risk of injury from high-current electrical energy