Display Messages
C-28 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
112 VOLUME #<n>
REBUILD FAILURE
Error
The rebuild operation on
the configured volume
failed.
If the volume is still
operating in regenerative
mode, remove the
replacement drive and
replace it with a different
new drive.
113 VOLUME #<n>
EXPANSION
FAILURE
Error The volume expansion
operation on the
configured volume failed.
Run ACU and determine the
state of the volume. If the
volume is still operational,
reattempt the operation.
114 VOLUME #<n>
STATE DELETED
Informational The configured volume is
deleted and no longer
available. Use ACU to
delete volumes.
120 CONFIGURED
VOLUMES <n>
Informational The controller detected
the specified number of
configured volumes at
power up.
continued
Zobrazit stránku 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 156 157

Komentáře k této Příručce

Žádné komentáře