Hp StorageWorks 500 Modular Smart Array Uživatelský manuál Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 157
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
Display Messages
C-32 HP StorageWorks Modular Smart Array 500 System User Guide
Table C-1: Display Messages continued
Message Type Description Action
202 ARRAY
CONTROLLER
OVERHEATING
Error The temperature sensor
on the array controller
indicates that the array
controller is exceeding
the normal operating
range.
1. Be sure that all
MSA500 system fans
are operating.
2. Replace any failed
fans.
3. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
203 ARRAY
CONTROLLER
OVERHEATED
Error The temperature sensor
on the array controller
indicates that the array
controller exceeded the
safe operating range.
1. Power down the
MSA500 system as
soon as possible to
avoid hardware failure.
2. Be sure that all
MSA500 system fans
are operating.
3. Replace any failed
fans.
4. Be sure that all bays
are populated with
components or blanks.
If this action does not solve
the problem, contact HP
support.
continued
Zobrazit stránku 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 156 157

Komentáře k této Příručce

Žádné komentáře