HP Designjet T Series — Service Manual 4-13
Service Calibrations
and press OK.
2 In the Drop Detector Calibration menu, scroll to Reset Calibration Flag
and press OK.
3 When the following message appears on the front panel, you must select
whether you would like to continue with the calibration by pressing the OK
key. Press Back or Cancel to exit the calibration.
4 The printer will start to reset the calibration flag.
5 Once the calibration is completed, the Front Panel will return to the menu.
6 Restart the printer, and the printer will automatically calibrate the drop
detec
tor.
Calibrate Drop Detector
Perform the Drop Detector Calibration as follows:
1 In the Service Calibrations submenu, scroll to Drop D
etector Calibration