Hp Surestore Disk Array 12h and FC60 Uživatelský manuál Strana 128

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 466
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 127
128 Topologies for HP-UX
Fibre Channel
cable
No on path to
failed cable;
Yes if array has
dual controller
modules and
alternate paths
have been
configured
I/O operations fail along the path through the failed cable. If the host
has two Fibre Channel adapters connected to a dual-controller module
disk array, the array can be accessed through the operational path if
primary and alternate paths have been configured in LVM. If so, LVM
switches automatically and transparently to the alternate path. The
authorized service provider hot-swaps the failed cable
Failing
component
Continue
after failure What happens and how to recover
Zobrazit stránku 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 465 466

Komentáře k této Příručce

Žádné komentáře