Hp Surestore Disk Array 12h and FC60 Uživatelský manuál Strana 343

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 466
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 342
Status Conditions and Sense Code Information 343
Managing the Disk Array
on HP-UX
A6 00 Recovered processor memory failure
The controller has detected and corrected a recoverable error
in processor memory.
A7 00 Recovered data buffer memory error
The controller has detected and corrected a recoverable error
in the data buffer memory.
Sense bytes 34-36 will contain the count of errors encountered
and recovered
C0 00 The Inter-controller Communications Have Failed
The controller has detected the failure of the communications
link between redundant controllers.
D0 06 Drive IO Time-out
The controller destination IO timer expired while waiting for a
drive command to complete.
D1 0A Drive Reported Busy Status
A drive returned a busy status in response to a command.
E0 XX Destination Channel Error
XX = 00 through 07 indicates the Sense Key returned by the
drive after a check condition status
XX = 10 indicates that a bus level error occurred
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation
Zobrazit stránku 342
1 2 ... 338 339 340 341 342 343 344 345 346 347 348 ... 465 466

Komentáře k této Příručce

Žádné komentáře