90 Recommended Disk Array Configurations
Maximum Capacity
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Four disk enclosures with ten 73 GByte disks each (40 disks total)
Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
LUN Configuration
Ten RAID 5 LUNs, each comprising four disks (3 data + 1 parity)
Each disk in a LUN is in a separate enclosure.
High Availability
Handles a single disk failure, single controller, single channel, single BCC, or a single
disk enclosure failure
Expansion requires powering down the disk array and adding additional disk
enclosures and cabling
Disk Capacity
Maximum capacity 2920 GBytes