HP C30D Uživatelský manuál Strana 288

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 483
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 287
(004 intentionally excluded)
5-10 Diagnostic Tests
011 Main Charger Test
1 Remove the photoconductor unit and place it in its protective packaging. Close the top
cover.
2 Go to: 011
3 Press: READY to run the test. The main charger turns on and off repeatedly.
4 Confirm that the display alternates between “0” and “1,” accompanied each time by a
brief tone. The display indicates the following:
These codes may indicate specific error conditions:
5 Press: STOP to exit.
6 Reinstall the photoconductor unit.
Table 5-7. Main Charger Test Displays
Display Indication
0 Main charger off
1 Main charger on
Table 5-8. Main Charger Test Error Displays
Display Indication
041 Photoconductor seam sensor short
045 Main charger short
046 Main charger open
4-1 You forgot to remove the photoconductor
Zobrazit stránku 287
1 2 ... 283 284 285 286 287 288 289 290 291 292 293 ... 482 483

Komentáře k této Příručce