Diagnostic Tests 5-11
012 Transfer Charger Test
1 Remove the photoconductor unit and place it in its protective packaging. Close the top
cover.
2 Go to: 012
3 Press: READY to run the test. The transfer charger turns on and off repeatedly.
4 Confirm that the display alternates between “0” and “1,” accompanied each time by a
brief tone. The display indicates the following:
These codes may indicate specific error conditions:
5 Press: STOP to exit.
6 Reinstall the photoconductor unit.
Table 5-9. Transfer Charger Test Displays
Display Indication
0 Transfer charger off
1 Transfer charger on
Table 5-10. Transfer Charger Test Error Displays
Display Indication
041 Seam sensor (sender) short
050 Transfer charger short
051 Transfer charger open or not installed
4-1 You forgot to remove the photoconductor