IO Timeouts for Sequential Devices Specifies the time (Time in seconds (0-999, 0 means
no-timeout)) which the host uses to timeout I/Os for the
following devices:
SCSI Device Type 01h - Sequential Access
IO Timeouts for Other Devices Specifies the time (Time in seconds (0-999, 0 means
no-timeout)) which the host uses to timeout I/Os for devices
other than:
SCSI Device Type 00h - Direct Access
SCSI Device Type 01h - Sequential Access
SCSI Device Type 04h - Write Once
SCSI Device Type 05h - CD-ROM
SCSI Device Type 07h - Optical
SCSI Device Type 0Eh - Simplified Direct Access
LUNs to Scan for Block Devices Controls LUN scans for the following devices with
Non-Removable Media:
SCSI Device Type 00h - Direct Access
SCSI Device Type 04h - Write Once
SCSI Device Type 07h - Optical
SCSI Device Type 0Eh - Simplified Direct Access
LUNs to Scan for Block Devices
(Removable)
Controls LUN scans for the following devices with
Removable Media:
SCSI Device Type 00h - Direct Access
SCSI Device Type 04h - Write Once
SCSI Device Type 05h - CD-ROM
SCSI Device Type 07h - Optical
SCSI Device Type 0Eh - Simplified Direct Access
LUNs to Scan for Sequential Devices Controls LUN scans for the following devices:
SCSI Device Type 01h - Sequential Access
LUNs to Scan for Other Devices Controls LUN scans for all devices other than the following:
SCSI Device Type 00h - Direct Access
SCSI Device Type 01h - Sequential Access
SCSI Device Type 04h - Write Once
SCSI Device Type 05h - CD-ROM
SCSI Device Type 07h - Optical
SCSI Device Type 0Eh - Simplified Direct Access
Spinup Properties Screen
To access Spinup Properties, press Enter on the Spinup Properties field from the Advanced
Adaptor Pr operties screen. This screen enables you to view and modify spin up specific settings.
Spin up refers to the disk drives getting up to rotation speed during system boot. To reduce the
power requirement stress on the backplane a delay is introduced between drive spin ups.
Direct Attached Spinup Delay Time, in seconds, between each disk drive spin up (default
3 seconds).
Direct Attached Max Targets Number of disk drives that spin up at the same time
(default 1 drive).
Expander Spinup Delay Expanders are not supported.
Expander Max Target Devices Expanders are not supported.
HP 8 Internal Port SAS HBA (SAS Controller) 297