Hp StorageWorks 1510i Modular Smart Array Uživatelský manuál Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 154
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
show prole
Description Displays detailed attribute information about supported host modes
(operating sy
stems).
Syntax show profile [ProleName]
Operands ProleName
[Optional] Limits the display to information about a specicprole. Valid
entries include:
windows—for Microsoft Windows servers.
linux—for Li
nux servers.
hp—for HP-UX servers.
openvms—for OpenVMS servers.
tru64—for T
ru64 UNIX servers.
solaris—for Solaris servers.
netware—for Netware servers.
xp—for XP se
rvers.
Example
CLI> show profile Linux
Profile name = Linux
Type = Standard Mode value = (000034a7)
Mode 0 = Peripheral Device LUN Addressing
Mode 1 = Asymmetric Failover
Mode 2 = Logical volumes connect as available on Backup Controller
Mode 3 = Product ID of ’MSA1000 VOLUME’ (only if Active-Standby mode)
Mode 4 = Normal bad block handling
Mode 5 = Logout all initiators on TPRLO
Mode 6 = Fault management events not reported through Unit Attention
Mode 7 = Send FCP response info with SCSI status
Mode8=Donotsend Unit Attention on failover
Mode 9 = SCSI inquiry revision field contains the actual version
Mode 10 = SCSI inquiry vendor ID=’HP’
Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout
Mode 12 = Enforce Force Unit Access on Write
Mode 13 = Admit Target Port on Reservation
Mode 14 = Asymmetrical Active/Active Operating Mode
See also add initiator