Hp StorageWorks 1510i Modular Smart Array Uživatelský manuál Strana 97

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 154
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 96
set this_controller|other_controller
Description Sets the baud rate for the CLI serial port on the specied controller.
NOTE:
When using this command, you must also adjust the terminal speed on
your client to match the setting. In dual-controller congurations, each
controller has its own setting. Changing the speed on one controller does
notaffecttheothercontroller.
Syntax set this_controller terminal_speed <speed>
or
set other_controller terminal_speed <speed>
Operands
this_controller
The controller to which the CLI session is connected.
other_controller
The other MSA controller.
terminal_speed <speed>
Thebaudrate,where<spee d > is one of the following values: 9600,
19200, 38400,or57600.
Example
set this_controller terminal_speed 57600
Set your terminal speed to 57600 now!Y/n?
newpage pi
1510i Modular Smart Array Command Line Interface user guide