HP NonStop Shadowbase Command Definitions
Monitor Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
34
MAXQMGR number
Initial Changed
Version Version Values Default Minimum Maximum Alter
4.090 0 0 255 No
Is the maximum number of Queue Managers which can be configured
within this AUDMON instance. The Queue Manager is an optional
component of HP Shadowbase: default value is 0, no Queue Managers
are configured within AUDMON. Must be set large enough to hold the
aggregate number of QMGRS established by the SET COLL MAXQMGR
settings for all collectors configured within this AUDMON.
MONITORRATE seconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.000 2.603 300 1 32767 Yes
Is the number of seconds to delay before AUDMON verifies to all objects
are in operating order. The default is 300 seconds (5 minutes). The
minimum is 1 second.
Note: Use caution in reducing this parameter. Significant system
resources are required for the processing associated with this
parameter. Setting it too low could also negatively impact HP
Shadowbase throughput.
NORUNTIMEOUT seconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.980C 4.060 Integer 900 0 32767 Yes
As of release v3.980C,a check was added to the HP Shadowbase monitor
AUDMON to evaluate if a RUN command has been entered after a
Collector has been started. It will also evaluate if a RESUME COLL
command has been entered after a SUSPEND COLL command. This
verification is done during the AUDMON monitoring cycle based upon the
AUD MONITORRATE parameter setting. The AUD parameter
NORUNTIMEOUT has been added to define the period of time in seconds
to use for the basis of these checks.
If the Collector is not in the “run” state, and the NORUNTIMEOUT duration
passes by, then when the verification is done during the monitoring cycle,
a critical EMS message will be output to identify the situation. A message
will continue to be sent every monitoring cycle, when a subsequent
NORUNTIMEOUT duration has past, if the Collector remains in a “started”
Komentáře k této Příručce