HP NonStop Shadowbase Command Definitions
Collector Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
83
PRI number
Initial Changed
Version Version Values Default Minimum Maximum Alter
1.000 None 1 199 No
Is the priority at which the Collector runs. The number can be from 1 to
199. If this parameter is omitted, the default is a priority of 20 less than
the priority of AUDMON.
PROCESS [\system. ] $coll_name
Initial Changed
Version Version Values Default Value Specifications Alter
1.000 None Valid process name (include NODE) No
This required parameter is the process name of the Collector on start-up.
PROGRAM [ \system.$volume.subvolume ] filename
Initial Changed
Version Version Values Default Value Specifications Alter
1.000 5.002 AUDCOLLN Valid program file name No
Is the name of the Collector object file. As of version 5.002, AUDCOLLN
will now be used by default as the program file name, as opposed to
AUDCOLL which was the default previously. Unless otherwise specified,
the volume and subvolume name used will be the same as the location of
the object file for AUDMON. Use AUDCOLL for Collectors processing
TMF audit trails using ARLIB and AUDCOLLN for Collectors reading non-
TMF audit trails files using ARLIB2.
PULSECLOCKADJ microseconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.990 0 -2147483647 2147483647 Yes
It is possible to configure HP Shadowbase such that the AUDMON runs
on a different HP NonStop node than a Collector process. In the event
that there is a discrepancy between the system clocks between the nodes,
the PULSECLOCKADJ parameter can be used to adjust the timestamps
recorded by a Collector for its pulse event processing. The adjustment
(positive or negative) value indicated by the PULSECLOCKADJ parameter
argument will be added to each of the pulse timestamps the Collector is
responsible for setting.