HP StorageWorks 2300 Modular Smart Array CLI reference guide 103
set spares
Description Designates spare disks for use by redundant (RAID 1, 3, 5, 6, 10, 50) vdisks.
A global spare is available to any redundant vdisk with the same disk type. The system can have
eight global spares. Each must have enough capacity to replace the smallest disk in any existing
vdisk.
A dedicated spare is assigned to a redundant vdisk with the same disk type. A vdisk can have four
spares. Each must have enough capacity to replace the smallest disk in that vdisk.
NOTE: Existing spares not specified in this command will become available disks.
Syntax
set spares disks disks [vdisk vdisk]
Parameters disks disks
IDs of the disks to designate as spares. For syntax, see Command syntax.
vdisk vdisk
Optional. Name or serial number of the vdisk to assign spares to. For syntax, see Command syntax.
If this parameter is omitted, the disks will be global spares.
Example Designate disk 1.2 as a global spare:
# set spares disks 1.2
Info: Command completed successfully. (1.2) - Global spare disk 1.2 was set.
Success: Command completed successfully.
Designate disk 1.3 as a dedicated spare for vdisk VD1:
# set spares disks 1.3 vdisk VD1
Info: Command completed successfully. (1.3) - Vdisk spare disk 1.3 was set.
Success: Command completed successfully.
See also show disks
show vdisks