HP Modular Smart Array 500 Starter Kit Uživatelská příručka Strana 110

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 186
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 109
110
Temperature Exceeded
Shows whether the system forces a controller shutdown if a temperature is detected that exceeds
system threshold limits.
Partner Notify
Shows whether the partner controller is notified if a trigger condition occurs.
Auto Write Back
Shows whether the cache mode automatically changes to write-back after the trigger condition is
cleared.
Example Show advanced system-configuration settings:
# show advanced-settings
Background Scrub: enabled
Partner Firmware Upgrade: disabled
Utility Priority: High
SMART: Enabled
Dynamic Spare Configuration: Disabled
Enclosure Polling Rate: 5
Host Control of Caching: enabled
Sync Cache Mode: Immediate
Missing LUN Response: Not Ready
Controller Failure: Disabled
SuperCap Failure: Enabled
CompactFlash Failure: Enabled
Power Supply Failure: Disabled
Fan Failure: Disabled
Temperature Exceeded: Disabled
Partner Notify: Disabled
Auto Write Back: Enabled
See also set advanced-settings
Zobrazit stránku 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 185 186

Komentáře k této Příručce

Žádné komentáře