HP Modular Smart Array 500 Starter Kit Uživatelská příručka Strana 175

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 186
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 174
HP StorageWorks 2300 Modular Smart Array CLI reference guide 175
verify vdisk
Description Verifies whether vdisk redundancy data is consistent with its user data. For RAID 3, 5, 6, and 50,
verify checks all parity blocks to find data-parity mismatches. For RAID 1 and 10, verify compares
the primary and secondary disks to find data inconsistencies.
Verification can last over an hour, depending on vdisk size, utility priority, and amount of I/O
activity. When verification is complete, the number of inconsistencies found is reported with event
code 21 (Vdisk verification complete) in the event log. Such inconsistencies can indicate
that a disk in the vdisk is going bad. You can use a vdisk while it is being verified.
Syntax
verify vdisk vdisks
Parameters vdisks
Name or serial number of the vdisks to verify. For syntax, see Command syntax.
Example Verify vdisk VD1:
# verify vdisk VD1
Info: Verify started on vdisk VD1
Success: Command completed successfully
See also abort verify
show vdisks