timeout #
Optional. Sets the timeout value in seconds for the login session. Valid values are 30–9999, where
9999 means do not timeout. The default is 1800 seconds (30 minutes).
type standard|advanced|diagnostic
Optional. Specifies the user's level of technical expertise, to control access to functions in the WBI.
• standard: Enables access to standard administrative functions. This is the default for monitor
users.
• advanced: Enables access to standard and advanced functions. This is the default for manage
users.
• diagnostic: Enables access to standard, advanced, and troubleshooting functions. This is the
default for manage users of the CLI.
units auto|MB|GB|TB
Optional. Sets the unit for display of storage-space sizes. auto lets the system determine the proper
unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully
display a size, the system uses a smaller unit for that size. Default is auto.
Example Create user John who will view system information using base 2 in WBI:
# create user John base 2 interfaces wbi level monitor
Enter Password for new user John:****
Re-enter Password:****
Info: level: monitor.
Info: interfaces: WBI
Info: The 'type' option was not specified; defaulting to 'standard'.
Info: The 'locale' option was not specified; defaulting to 'English'.
Info: base: 2.
Info: The 'precision' option was not specified; defaulting to '1'.
Info: The 'units' option was not specified; defaulting to 'auto'.
Info: The 'temperature-scale' option was not specified; defaulting to 'celsius'.
Info: The 'timeout' option was not specified; defaulting to '1800' seconds (30
minutes).
Success: Command completed successfully. - The new user was created.