set host-parameters
Description For FC , sets controller host port parameters for communication with attached hosts. The new settings
take effect without restarting the controllers.
Syntax
set host-parameters [controller a|b|both] [speed 1g|2g|4g|auto] [ports #|all]
[fibre-connection-mode loop|point-to-point] [prompt yes|no|y|n|expert]
[noprompt]
Parameters controller a|b|both
Optional. Specifies whether to apply the settings to controller A, B, or both. Required if either speed
or fibre-connection-mode is specified.
speed 1g|2g|4g|auto
Optional. For FC, the link speed in Gbit/sec.
ports #|all
Optional. A host port number or all ports. If this parameter is omitted, all host ports on the specified
controllers are affected.
fibre-connection-mode loop|point-to-point
Optional. For FC, sets the topology for the specified ports to either:
loop: Fibre Channel-Arbitrated Loop (public or private)
point-to-point: Fibre Channel point-to-point.
noprompt
Optional. Specifies an automatic response to the confirmation prompt that enables the operation to
proceed. If this parameter is omitted, you must reply to the prompt.
Example On an FC storage system, set the link speed to 2 Gbit/sec for ports A1 and B1:
# set host-parameters speed 2g ports a1,b1
WARNING: This change will take effect immediately. Changes may affect access to
data. Are you sure? yes
See also show host-parameters