Viewing system information4–26
Figure 4-5 A graph showing the information in the ost-blkD.cfg file
4.7.4 Viewing information in the /proc file system
The following information is gathered and stored in the /proc file system:
SCSI disk statistics — /proc/scsi/sd_iostats
Read size distribution
Write size distribution
CCISS disk statistics — /proc/driver/cciss/cciss_iostats/
Read size distribution
Write size distribution
Time distribution of read and write I/O requests
OST block statistics — /proc/fs/lustre/obdfilter/
Read size distribution
Write size distribution
Note the following points:
Information about disks on EVA4000 arrays is stored in the /proc/scsi/sd_iostats directory.
Information about disks on SFS20 storage arrays is stored in the /proc/driver/cciss/
cciss_iostats/ directory
Information about the local disk on each HP SFS server (usually named c0d0) is stored in the
/proc/driver/cciss/cciss_iostats/ directory. This information is not relevant to the
performance of the file systems.